Warmington TFG 800 Скачать руководство пользователя страница 5

5 September 2019

 

All dimensions are in mm

 

Copyright

 

5

 

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.

 

Your purchase of the Warmington traditional fire gas burner (included in the price of the firebox) comes with multiple options for lighting/ heat 
settings. The most affordable option is the ‘SG’ option, which is a manual start, manual adjustment option, working much like a barbeque. 
Alternatively, Warmington offers several electronic options

-

 ‘ON

-

OFF’ with a switch at the wall to operate the fire, or ‘ON

-

OFF

-

HIGH

-

LOW’ 

with two settings for heat output. Furthermore, a fully adjustable electronic ‘EG’ option is available, supplied with remote control. 

 

OPERATION OF A WARMINGTON SG GAS FIRE (MANUAL START)

 

To light:

 

 

• 

Open

 

 the front cover by pulling it outwards

 

• 

Push in the ignition control switch and hold in the 

‘PILOT’

 position for 5

-

10 seconds until you can 

hear the gas come through the pipe, making sure the ignition switch is pressed in firmly.

 

• 

To strike the igniter, turn anti clockwise to the 

*STAR

 position (

w

ith the ignition switch still firmly 

pressed in

until you hear the pilot ignite with a ‘click’.

 

Repeat this process 2 or 3 times if 

necessary.

 

• 

Once the pilot flame is lit, hold this position for 3

-

5 seconds, then gently let the ignition switch out 

and set the flame control to high.

 

 It may take a few seconds for the burner to light all the way 

across.

 

• 

Once the flame is established, adjust to the desired setting and close the cover.

 

To shut down:

 

 

• 

Open the cover by pulling it outwards.

 

• 

Turn the control ignition switch to 

‘PILOT’

 and the flame bed will extinguish. Pilot light may be left on and the pilot flame will still 

burn. 

 

• 

To fully extinguish, turn to the 

‘OFF’

 position before closing the cover.

 

 

 

OPERATION OF A WARMINGTON EG ELECTRONIC GAS FIRE 

 

AS SHOWN FROM THE FRONT OF THE BURNER

 

This control panel is located on the bottom left hand side 
of your Warmington decorative gas fire.

 

Press and release the power button. This will start the 
electronic spark and the power LED will be on 
permanently . The pilot will ignite first and once this is on, 
it will ignite the main burner.  Pressing and releasing the 
power button again will switch off the appliance.

 

When the appliance is turned on again, the gas fire will resume the previous flame and fan settings, unless the appliance was switched off 
due to power failure.  In the circumstance of a power failure the Remote Control System will return to the default settings which is a low 
flame and the fan turned off.

 

If the gas fails to light, the appliance it will go into lock out mode, after trying to ignite for 1 minute (approx.). In lock out mode the power 
LED will remain illuminated.  To start the appliance again, press and release the power button twice after the gas supply resumes.

 

REMOTE CONTROL 

 

Your remote control has all the features of the control receiver situated on the front panel of the 
burner. 

 

By pressing the timer button, the power LED will start flashing and after 30 minutes the appliance 
will shut off automatically. By pressing the timer button again within the 30 minute period, this will 
reset the timer and the power LED will stop flashing.

 

Press and hold the 

+

 button to increase the main burner flame.  

 

Press and hold the 

-

 

button to decrease the main burner Flame. 

 

By holding the 

or 

-

 flame button for up to 10

-

15 seconds,  this will increase or decrease the 

main burner flame to it’s max or min.

 

The Warmington decorative gas fire has a 3 Speed Fan and its operated independent from the 
main burner. This is done by pressing and releasing the fan 

+

 or 

– 

button will increase or 

decrease the fan speed. The LED on the front panel will indicate the fan settings at low, medium, 
or high speed. Pressing and releasing of the button will lower the speed until the fan is turned off.

 

Содержание TFG 800

Страница 1: ...ence Ensure that you have the correct and current installation details for the Warmington Fire Installation The Warmington unit is to be installed by a certified Warmington installer or an approved NZ...

Страница 2: ...c Perf Extension 2 Back Air Brick 1 NOT Supplied sold separately No Warmington Fluekit 1 Fire Bricks H40 75X115X230mm Other Sizes Available Varied Fire Brick Refractory Mortar 1 Autoclaved Aerated Con...

Страница 3: ...atural convection exits through the vents at the top of the cavity or through the liner and out of a venting cone in the case of venting through the flashing 1 2 3 3 4 POINTS TO CONSIDER PRIOR TO INST...

Страница 4: ...supply valve beside your meter Call your gas supplier gasfitter or the fire service for further advice GENERAL REQUIREMENTS FLUED GAS APPLIANCES All gas fires requiring Warmington Flue Systems shall b...

Страница 5: ...G ELECTRONIC GAS FIRE AS SHOWN FROM THE FRONT OF THE BURNER This control panel is located on the bottom left hand side of your Warmington decorative gas fire Press and release the power button This wi...

Страница 6: ...ce requirements Construct framing or block surround according to relevant minimum dimensions as referenced on pages 6 to 9 After framing surround is complete construct plinth to required height see pa...

Страница 7: ...DETAILS HEAT CELL CLEARANCE Description TFG 800 TFG 1000 TFG 1200 To centre of flue J 539 538 589 Flue diameter K 300 300 350 Liner diameter L 400 400 450 Heat cell clearance width M 1290 1490 1690 H...

Страница 8: ...00 600 750 Block clearance width R 1610 1610 2010 Block clearance depth S 1000 1000 1200 Block enclosure height U 2390 2390 2390 To centre of flue V 639 638 689 Chimney chase clearance X 500 500 550 N...

Страница 9: ...h RR 1590 1990 1990 Solid poured top depth SS 1190 1190 1190 Block enclosure height TT 2390 2390 2390 To centre of flue UU 554 553 604 Chimney chase clearance X 500 500 550 Note Centreline of flue is...

Страница 10: ...to firebox using supplied M8 bolts nuts and washers Ensure that exhaust sealant is used between fire and adaptor Construct autoclaved aerated concrete AAC enclosure around traditional firebox Insert...

Страница 11: ...ard of the front face of the fireback or where the gas burner is expected to be placed Additionally lay up the first layer s of the fireback leaving one brick s worth of a gap in the centre of the bas...

Страница 12: ...anels 2400x600x75 Power Panels are required for basic heat cell construction as shown in detail Firebox with Hebel Surround Visit www warmington co nz site for AAC instructions PDF download 2 3 2 TFG...

Страница 13: ...Pressure High kPa 1 1 1 Burner Pressure Low kPa 0 3 0 3 0 3 MJ h 35 61 27 Flame Effect Output Only Effect Effect Effect Supply Pipe Size minimum diameter 3 8 1 2 3 8 Lab Test No GL 923 WAR 0115 0121...

Страница 14: ...effect Fit burner grate by sliding R L side metal pins on grate into holes located on burner side plates as shown 2 Top Row Slide R LH grate pins into holes located on the burner side 1 Bottom Row Tot...

Страница 15: ...to the hi kPa value in the table for maximum output test point inlet Modulator Harness Connections 1 2 BSPT gas outlet SIT 840 Control Valve test point outlet 1 2 BSPT gas inlet adjustment screw Afte...

Страница 16: ...5 September 2019 All dimensions are in mm Copyright 16 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification...

Страница 17: ...between the hi and the low pressures test point inlet HI LOW Harness Connections test point outlet 1 2 BSPT Gas outlet SIT 843 Control Valve Nut A High setting adjustment screw Screw B Low setting ad...

Страница 18: ...5 September 2019 All dimensions are in mm Copyright 18 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification...

Страница 19: ...asfitter Light appliance adjust to high flame setting and check pressure adjust to low flame and check pressure If adjustments are necessary remove the cap The pressure adjustment screw and nut are on...

Страница 20: ...tisfied that the appliance is working correctly fit the front panel assembly back to the gas burner NOTE Ensure you peel the Protective Plastic Coating from any stainless steel components if fitted Al...

Страница 21: ...5 September 2019 All dimensions are in mm Copyright 21 Due to continued product improvement Warmington Ind LTD reserves the right to change product specifications without prior notification...

Страница 22: ...e base screw and check for leaks Correct operation of 3 Flame Pilot 3 Flame Pilot in 3 7 COMMISIONING AND TESTING Read all the instructions before commissioning Install coals and logs and burner befor...

Страница 23: ...graph for a selected model of traditional fire is an acceptable hearth extension A hearth extension BELOW the curved minimum requirement line is NOT acceptable 4 1 COMBUSTIBLE MANTLE CLEARANCES REF B...

Страница 24: ...ue pipe is 5mm lower that the Flashing cone 5 Fit the Top Spider into position ensure that the legs of the spider are fitted inside the liner and that the spider is positioned hard down onto the liner...

Страница 25: ...LINED FLUE SYSTEM FLUE PENETRATION VENTED THROUGH TOP FLASHING Note Flue system casing Flue system may require to be Doubled lined to comply Ref ASNZS 2918 2001 4 3 Flue pipe casing Notes External re...

Страница 26: ...tion CHIMNEY CHASE FLASHING AND AIR VENTILATION OP TIONS SETTING ADD COWL AND FLASHING CONE HEIGHT Note Flashing Spigot height is determined by the Insulation that is fitted under the Flashing See Det...

Страница 27: ...ations without prior notification FLUE HEIGHT MINIMUM DETAILS FRAME OUT AND TRIM OUT DETAILS FOR CHIMNEY CHASE Option X Singled Lined Flue System Option Y Double Lined Flue System The flue exits are t...

Страница 28: ...E APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING TESTED TO AS NZS 4013 ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSI...