7
testing.
•
Light fire pit. It may take several cycles to purge air from the
lines.
o
For electronic ignition models apply proper 110VAC or 24
VAC.
•
Once fire pit is lit perform leak test on all gas connections. Repair
as needed.
•
Turn off fire pit and allow to cool.
•
Apply media as described in (Section 5).
•
Turn on fire pit again and perform leak test with media correctly
installed. If gas leak is detected verify correct media application
and repair as needed.
•
Set fire pit in properly constructed enclosure (Section 3).
•
Verify correct operation and lighting.
•
Review safety manual with end user and instruct not to change/
modify fire pit or media.
•
Leave manual with end user.
IMPORTANT:
On electronic ignition models please apply the Start Up
and Shutdown decal next to control switch in an obvious position.
5) Media
Warning: FOR GLASS MEDIA USAGE WITH LP GAS- WHEN
USING APPROVED DECORATIVE GLASS TO COVER BURNER APPLY
ONLY ENOUGH TO HIDE BURNER. APPLYING OVER 1/2” MAY
CREATE BACK PRESSURE AND GAS LEAKAGE FROM AIR MIXER
RESULTING IN LP POOLING UNDER FIRE PIT.
Warning: FOR GLASS MEDIA USAGE WITH LP GAS- THE UNIT
MUST BE TESTED WITH MEDIA OVER BURNER FOR
CONFIRMATION OF NO BACK PRESSURE CREATING GAS TO LEAK
OUT OF AIR MIXER VENTURI HOLES. THIS MAY HAVE TO BE DONE
PRIOR TO PLACING IN ENCLOSURE IF NO ACCESS DOOR.
Warning:
The fire pit is designed to use approved media correctly
installed over the burner to achieve proper combustion.
WARRANTY REQUIREMENT:
Never install a mesh or screen under the
media.
IMPORTANT:
Media affects flame pattern greatly. It is possible to
create an unusual flame pattern that could damage your enclosure.
Enclosure damage from an open flame fire feature is not covered under
any warranty.
Lava Rock & Glass Application
Please follow the instructions below to add the finishing touch to your fire
pit. Remember the deeper your lava rock or glass the more risk of
reducing if not smothering the flame. Particular attention needs to be on
the pilot assembly area. Incorrect media installation will cause the pilot
flame to suffocate and turn off pit or delay main burner ignition.
Содержание CFB60LP
Страница 1: ... 1 DESIGN CERTIFIED CROSSFIRE SYSTEMS HMLS60 24V LP NG DMLS60 3V LP NG MLS60 LP NG ...
Страница 17: ... 17 HMLS60 with LP or NG with Honeywell Electronic Spark Ignition System ...
Страница 18: ... 18 DMSL60 with LP or NG with Dexan 3 Volt Battery or 110 Ignition System ...
Страница 19: ... 19 MLS60 with LP or NG Regulator ...
Страница 20: ... 20 System Tags and Markings ...
Страница 21: ... 21 ...
Страница 22: ... 22 ...
Страница 23: ... 23 ...