6
4) Fire Pit Installation
***We suggest that our products be installed by professionals that are
locally licensed by the authority having jurisdiction in gas piping.
Warning:
We suggest that our products be installed by professionals
that are locally licensed by the authority having jurisdiction in gas piping.
Warning:
We suggest that our products be serviced annually by a
professional certified in the US by the National Fireplace Institute (NFI)
as NFI Gas Specialists.
Warning:
Confirm this appliance is built for gas used – natural gas
or LP. Do not use natural gas appliance with LP or LP appliance with
natural gas. Refer to the label on the appliance.
Warning:
To prevent damage, unhook fire pit from gas supply for
pressure leak tests.
Warning:
Fuel line sizing is the responsibility of the installer and
must be able to supply the stated maximum 60K BTU for the product.
Natural gas 3.5” WC pressure and for propane 10” WC pressure.
Warning:
Burn Testing- It is the responsibility of the qualified
installer to test for gas leaks at all connections.
Warning:
When filling the pan with lava rock and/or decorative
glass, the instructions in Section 5 must be followed.
Warning:
Gas Plumbing Connections: Use only joint compound or
tape that is resistant to all gases. Apply joint compound to all male pipe
fittings only- DO NOT use on FLARED fittings. Be sure to tighten every
joint securely.
Warning:
For systems with an extended or detached valve box the
area in which the valve box is installed must conform with all installation
requirements to include but not limited to location, construction, venting
and local codes. Failure to do so may result inpersonal injury property
damage or explosion.
WARRANTY REQUIREMENT:
Warranty is void if valve box is opened
•
Purge gas lines of air.
•
Perform all leak test with leak detector or leak reactant.
•
Verify correct gas type and pressure.
•
Perform leak test on main gas supply. Repair leaks as necessary.
•
Shut Off Gas Supply and Power to fire-pit.
•
Connect fire-pit to main gas supply. If using flex line avoid sharp
bends with flex line to prevent whistling.
•
Turn on gas supply and perform leak test on all inlet connections.
Repair as needed.
•
For electronic ignition models hook up proper 110VAC or 24VAC
electrical power following all local codes.
•
On electronic ignition models The 6’ power cord can be either tied
into the main power supply for use with wall switch or plugged
into remote receiver to use remotely.
•
Position fire pit safely with access to all gas connections for
Содержание CFB60LP
Страница 1: ... 1 DESIGN CERTIFIED CROSSFIRE SYSTEMS HMLS60 24V LP NG DMLS60 3V LP NG MLS60 LP NG ...
Страница 17: ... 17 HMLS60 with LP or NG with Honeywell Electronic Spark Ignition System ...
Страница 18: ... 18 DMSL60 with LP or NG with Dexan 3 Volt Battery or 110 Ignition System ...
Страница 19: ... 19 MLS60 with LP or NG Regulator ...
Страница 20: ... 20 System Tags and Markings ...
Страница 21: ... 21 ...
Страница 22: ... 22 ...
Страница 23: ... 23 ...