REPLACEMENT PARTS

PBIK 

Push Button Ignition Kit: spark igniter rod and wire + push button battery operated control module

PB-SI

Spark igniter rod and wire

PB-CM

Push button battery operated control module

MBR

Mounting Bracket

3VIK-NG / 3VIK-LP

3V Ignition System

3VCM 

3V Control Module 

3VPA-NG / 3VPA-LP

3V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage)

3VGV-NG / 3VGV-LP

3V 120K BTU Capacity Gas Valve

3VBP

3V Battery Pack

24VIKHC-NG / 24VIKHC-LP

Standard 24V Ignition System (High Capacity)

24VGVHC-NG / 24VGVHC-LP

24V 400K BTU Capacity Gas Valve (High Capacity)

24VCM 

24V Control Module for use with Standard Ignition Systems (HC)

24VPA-NG / 24VPA-LP

24V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage) for use with Standard Ignition Systems (HC)

24VT

24 Volt Transformer for use with all 24 Volt Ignition Systems (Spark & Hot Surface Ignitions)

P24VIKSC-NG / P24VIKSC-LP

Premium 24V Ignition System (Standard Capacity)

P24VCBSC

Premium 24V 290K BTU Capacity Control Box (Standard Capacity)

P24VIKHC-NG / P24VIKHC-LP

Premium 24V Ignition System (High Capacity)

P24VCBHC

Premium 24V 512K BTU Capacity Control Box  (High Capacity)

P24VIKPA-NG / P24VIKPA-LP

Premium 24V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage) for use with Premium Ignition Systems (SC & HC)

P24VIKWC

Wind Cage

FLKV12

½” Flex Line and Key Valve. For use with any burner up to 120K BTU’s. Kit Includes: (1) 36” L x ½” Diameter Flex Line + ½” Key Valve + 3” and 12” Key

FLKV34

3/4” Flex Line and Key Valve. For use with any 121K - 249K BTU Burner. Kit Includes: (1) 36” L x 3/4” Diameter Flex Line + 3/4” Key Valve + 3” and 12” Key

FLKV34FIT180

3/4” Flex Line, Key Valve, and FIT180. For use with any 121K - 249K BTU Burner. Kit Includes: (1) 36” L x 3/4” Diameter Flex Line + 3/4” Key Valve + 3” and 12” Key + ½” x 

2” Nipple to connect threaded inside 3/4” Flex Line Flare Connector to ½” Plate Coupling

DFLKV34

2x 3/4” Flex Lines and Key Valve. For use with any burner over 249K BTU’s. Kit Includes: (2) 36” L x 3/4” Diameter Flex Lines with + 3/4” Key Valve + 3” and 12” Key

DFLKV34FIT250

2x 3/4” Flex Lines, Key Valve, and FIT250. For use with any burner over 249K BTU’s. Kit Includes: (2) 36” L x 3/4” Diameter Flex Lines + 3/4” Key Valve + 3” and 12” Key + 

(1) 3/4” x ½” MM Reducer Fitting and (1) 3/4” Tee for connection at ½” Plate Co (1) 3/4” x 3” Nipple and (1) 3/4” Tee for Key Valve connection

DFLKV34FIT300

2x 3/4” Flex Lines, Key Valve, and FIT300. For use with any 300K+ BTU Burner. Kit Includes: (2) 36” L x 3/4” Diameter Flex Lines + 3/4” Key Valve + 3” and 12” Key + (1) 3/4” 

x 3” Nipple and (1) 3/4” Tee for connection at 3/4” Plate Co (1) 3/4” Tee for Key Valve connection

FIT180

Flex Line & Key Valve Connection Fitting for use with any burner over 249K BTU’s. Kit includes: (1) ½” x 2” Nipple. Connects ½” Plate Coupling to inside threaded 3/4” 

Flex Line Flare Connector

FIT250

Flex Line & Key Valve Connection Fittings for 250K - 299K BTU Burner. Kit includes: (1) 3/4” x ½” MM Reducer Fitting and (1) 3/4” Tee for connection at ½” Plate 

Co (1) 3/4” x 3” Nipple and (1) 3/4” Tee for Key Valve connection. Connects ½” Plate Coupling to two 3/4” Flex Lines + connection of two 3/4” Flex Lines to 3/4” 

Key Valve.

FIT300

Flex Line & Key Valve Connection Fittings for 300k+ BTU Burner. Kit includes: (1) 3/4” x 3” Nipple and (1) 3/4” Tee for connection at 3/4” Plate Co (1) 3/4” x 3” 

Nipple and (1) 3/4” Tee for Key Valve connection. Connects 3/4” Plate Coupling to two 3/4” Flex Lines and two 3/4” Flex Lines to 3/4” Key Valve.

FL3612

36” L x ½” Diameter Flex Line (MM)

KV12

½” Key Valve + 3” Key

KEY3

3” Key

DRIPLEG12

½” Drip Leg Kit

LPRH

Liquid Propane Regulator mounted on 5/16” 10’ Hose with handwheel quick connect. For use up to 200K BTU”s with a 20LB Propane Tank.

LPHOSE10

Liquid Propane 5/16”- 10’ Hose. For use with a 20LB Propane Tank

REGNG125

Regulator: 1/2” FNPT Inlet x ½” FNPT  For use up to 125K BTU’s - Natural Gas

REGLP200

Regulator 3/8 in. NPT Female Outlet 200K BTU/hr capacity. Maximum inlet pressure 250 psi. Low pressure outlet 11 in. W.C. Liquid Propane

FPVK

Fire Pit Vent Kit:  (2) 5.75” x 11.5” Vents + 18 square inches of vent area per vent

FL3634

36” L x 3/4” Diameter Flex Line  (MM)

KV34

3/4” Key Valve + 3” Key

KEY24

24” Key

DRIPLEG34

3/4” Drip Leg Kit

KEY12

12” Key

P24VIKCGPA-NG/ P24VIKCGPA-LP

24 Volt Hot Surface Ignition Pilot Assembly (Dual Pilot Tubes + I Igniter B Wind Cage) for use with Hot Surface Igni-

tion Systems (Standard & High Capacity)

P24VCBSCCG

24 Volt Hot Surface Ignition 290K BTU Standard Capacity Control Box with Dual Pilot Connections

P24VCBHCCG

Premium 24 Volt  512K BTU High Capacity Control Box with Dual Pilot Connections

www.warming-trends.com/patents

PATENTED

Содержание CFBL170 NG

Страница 1: ...nformation for the safe installation and operation of your Warming Trends fire feature You must read this manual in its entirety prior to installation and or operation Failure to follow these instruct...

Страница 2: ...t Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and l...

Страница 3: ...un incendie ou une explosion pouvant causer des dommages mat riels des blessures ou la mort AVERTISSEMENT Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans...

Страница 4: ...NG LP with 24VIKSC Model CFBL190 NG LP with 24VIKSC Model CFB60 2XL NG LP with 24VIKSC Model CFBH120 NG LP with 24VIKSC Model CFBH160 NG LP with 24VIKSC Model CFBH200 NG LP with 24VIKSC Model CFBT110...

Страница 5: ...s not responsible for damage due to improperly installed or operated units Installers must leave this manual with the end user Instructions are updated as needed and it is the installer or owners resp...

Страница 6: ...st be located far enough away that there is no risk of ignition IMPORTANT It is recommended that material such as granite marble or other dense stone be kept an appropriate distance away from flame du...

Страница 7: ...or emergency shut off and maintenance WARNING For electronic ignition models there must be an electrical shutoff wall switch or breaker on the exterior of the appliance or on adjacent structure to all...

Страница 8: ...or models that include electronic ignitions be sure to have a qualified electrician install proper power supply following all local codes 6 Inspect flex line s for punctures or breaks in line s 7 Make...

Страница 9: ...ze and extended use Ready to Finish Kits come with Fire Pit Vent Kit FPVK Vents do not come pre installed on Ready to Finish Fire Pit Vent Kits must be installed on site 19 Only use fire rated media g...

Страница 10: ...ng provided by inserting 1 2 x 2 Nipple into interior threads of the Flared Fitting Tighten Then connect the 1 2 x 2 Nipple fitting into the coupling located on the bottom of the aluminum plate Tighte...

Страница 11: ...Flex Line to the Flared Fitting that is now connected to the Key Valve Connect Escutcheon Plate to Key Valve through vessel wall Tighten Flared Fitting Coupling Flared Fitting Whistle Free Flex Line K...

Страница 12: ...ling Do not use the 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitting to 1 2 Coupling located on the bottom of the aluminum plate Then connect 3 4 Tee to 1 2 x 3 4 Reducing Fitti...

Страница 13: ...Fittings connected to the aluminum plate and Coupling Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall T...

Страница 14: ...ey Valve 1 2 x 2 Nipple 12 Key STEP 1 FIT180 Whistle Free Flex Line Plate 3 Connect to Coupling FK1 Connect one 1 2 Flared Fitting removed in Step 2 to 1 2 x 2 Nipple fitting provided by inserting 1 2...

Страница 15: ...ND KEY VALVE FK1 Connect Whistle Free Flex Line to Flared Fitting connection at ignition and then to Key Valve connection in Step 5 Connect Escutcheon Plate to Key Valve through vessel wall Tighten 6...

Страница 16: ...le Free Flex Line 24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K 300K BTU Systems 3 Connect to Coupling FK2 Do not use 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitt...

Страница 17: ...LT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K 300K BTU SYSTEMS CONTINUED Plate Coupling 3 4 Tee Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 1 2 x 3 4 Reducing F...

Страница 18: ...onnect ends of 3 4 Whistle Free Flex Lines to Flared Fittings connected to the 24 Volt Ignition Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheo...

Страница 19: ...g needle nose pliers Be careful not to break connectors Wires can go in either connection Push Button Module Spark Igniter Wires Key Valve Mounting Bracket Jet Drill Here Spark Igniter Stem 125 Plate...

Страница 20: ...desired flame pattern For electronic ignition systems do not block cover or obstruct pilot assembly Blocking covering or placing ceramic logs too close to pilot may cause excessive heat on pilot causi...

Страница 21: ...al injury or death 3 Confirm that your Natural Gas or Liquid Propane sup ply to the appliance is open or on 4 Before lighting visually inspect fire feature and remove any accumulated leaves or other c...

Страница 22: ...debris 5 Locate key valve or gas control valve controlling gas supply to your appliance 6 Locate the jet tip nearest the lighting opening described above that can be easily accessed while operating k...

Страница 23: ...thout sharp bends and installed correctly Check the pressure to be sure it is within recommended ranges Contact a certified gas technician for service and re pair if these suggestions do not solve the...

Страница 24: ...s for the Burners without charge If a Burner does not function as warranted during the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2...

Страница 25: ...ifor nia to cause cancer or reproductive toxicity go to https oehha ca gov proposition 65 proposition 65 list Warnings Lead Can cause birth defects or other reproductive harm Lead can be found in bras...

Страница 26: ...x Lines 3 4 Key Valve 3 and 12 Key 1 3 4 x 1 2 MM Reducer Fitting and 1 3 4 Tee for connection at 1 2 Plate Coupling 1 3 4 x 3 Nipple and 1 3 4 Tee for Key Valve connection DFLKV34FIT300 2x 3 4 Flex L...

Отзывы: