Warming Trends CFBL170 NG Скачать руководство пользователя страница 21

www.Warming-Trends.com  |  303 346 2224  |  [email protected]

21

7.  Place a lit lighter or match flame on or slightly above 

the tip of the jet located in Step 6 while not reaching 

over it. A long reach lighter or match is recommended.

8.  While holding the flame on or slightly above the jet 

tip as described in Step 7 above, slowly turn the key 

valve or gas control knob to the left to allow a mini-

mal flow of gas to the burner and light the selected 

jet. While attempting to light jet, do not substantially 

increase gas supply. Excessive flow of gas before jet is 

lit can cause pooling of gas and result in sudden flare 

up. Failure to follow these instructions could result 

in fire or explosion, which could cause property 

damage, personal injury or death.

9.  Once the selected jet (or other jets) is lit, continue to 

keep any body parts from above the pit or burner and 

slowly turn the key valve or gas control knob further 

to the left to increase the flow of gas to the burner. 

The other jets of the burner should ignite.

10.  You may follow the same procedure described above to 

light additional jets only if able to do so without reach-

ing across the burner or other jets which may ignite.

11.  If the flame will not stay lit after several attempts, turn 

the key valve to the off position and call your local 

technician or gas supplier for service prior to re-at-

tempting to operate your appliance.

12.  Once lit, use the key valve to adjust the flame to the 

desired height.

TURNING OFF YOUR MATCH LIT SYSTEM 

1.  Use key to turn valve to OFF position by turning key 

to the right.

2.  Verify flame is OUT. 

3.  If using LP bottle/tank – turn bottle/tank to CLOSED 

position.

4.  Allow to cool completely, then cover the fire feature 

with waterproof/weatherproof cover.

TURNING ON YOUR ELECTRONIC IGNITION SYSTEMS
WARNING:
 For electronic ignition models requiring pow-

er supply — a qualified, licensed electrician must install 

power supply. An outdoor NEMA rated GFCI Receptacle 

outlet should be installed within the interior of the enclo-

sure above grade to supply power to system. 

1.  STOP! Read all the safety information and warnings in the 

Installation Manual before attempting to light fire feature. 

2.  Any cover must be removed prior to operation of 

burner and must remain off during operation. 

Danger: Fire or Explosion Hazard. If you smell gas, 

shut off gas to the appliance, extinguish any open 

flame. If odor continues, leave the area immedi-

ately. After leaving the area, call your gas supplier 

or fire department. Failure to follow these instruc-

tions could result in fire or explosion, which could 

cause property damage, personal injury or death.

3.  Confirm that your Natural Gas or Liquid Propane sup-

ply to the appliance is open or on. 

4.  Before lighting, visually inspect fire feature and remove 

any accumulated leaves or other combustible debris.  

5.  If you do not smell gas, use the key to turn the key 

valve or gas control valve to the ON position by turn-

ing the key to the left. 

6.  Turn on power to the fire feature with switch, button, 

or remote. Within 10 seconds of power application 

Pilot Flame should be lit and visible. Once the pi-

lot is lit, the main burner will ignite shortly after. For 

Push Button: Press push button ignition and listen for 

clicking noise which indicates electrode is firing. Gas 

should ignite after a few clicks.

7.  Use key valve to adjust flame to desired height.
TURNING OFF YOUR ELECTRONIC IGNITION SYSTEMS

1.  Turn off power to fire feature — with remote control or 

wall switch. 

2.  Turn key valve to OFF position by turning key to the right.

3.  If using LP bottle/tank — turn bottle/tank to CLOSED 

position.

4.  Verify flame is OUT. 

5.  After allowing for ample cooling time, cover the fire 

feature with waterproof/weatherproof cover.

WARNING: FOR REMOTE CONTROL USE: To prevent 

unwanted startup turn off power to the appliance 

when not in use.
WARNING: 
If fire feature fails to turn off completely (small 

flames still visible), turn off gas supply using the main 

valve by your meter, and contact your gas supplier or 

qualified technician.
WARNING: For electronic ignition systems, which have 

an extended or detached valve box, the area in which the 

valve box is installed must conform with all installation 

requirements, including, but not limited to location, con-

struction, venting and local codes. Failure to do so may 

result in property damage, personal injury, or death. 

FIRESTORM

TM

 STEEL 

GAS LOG OWNER 

INFORMATION AND 

INSTALLATION

Thank you for your purchase of a FireStorm

TM

 Steel Gas Log 

from Warming Trends. We appreciate your business and hope 

that you enjoy your FireStorm

TM

 for many years to come!

Burner System Installation and Operating Instructions

Please read and follow the entire Warming Trends Own-

er’s Guide and Instruction Manual to install and operate 

your outdoor gas burner system. During the installation 

of your burner system, for safe lighting, orient the 

burner so that one end of it is easily reachable while 

operating the key valve.

Please follow all instructions of this Owner’s Manual 

regarding the use of approved media coverage over 

the burner. The approved media will form a bed upon 

which to place the FireStorm Steel Gas Log. It is recom-

mended that a flat bed of media two inches wider and 

longer than the FireStorm Steel Gas Log be formed.

INSTALLATION OF THE FIRESTORM STEEL GAS LOG

Your FireStorm Steel Gas Log may have sharp edges. 

Please handle carefully or wear appropriate gloves when-

Содержание CFBL170 NG

Страница 1: ...nformation for the safe installation and operation of your Warming Trends fire feature You must read this manual in its entirety prior to installation and or operation Failure to follow these instruct...

Страница 2: ...t Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and l...

Страница 3: ...un incendie ou une explosion pouvant causer des dommages mat riels des blessures ou la mort AVERTISSEMENT Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans...

Страница 4: ...NG LP with 24VIKSC Model CFBL190 NG LP with 24VIKSC Model CFB60 2XL NG LP with 24VIKSC Model CFBH120 NG LP with 24VIKSC Model CFBH160 NG LP with 24VIKSC Model CFBH200 NG LP with 24VIKSC Model CFBT110...

Страница 5: ...s not responsible for damage due to improperly installed or operated units Installers must leave this manual with the end user Instructions are updated as needed and it is the installer or owners resp...

Страница 6: ...st be located far enough away that there is no risk of ignition IMPORTANT It is recommended that material such as granite marble or other dense stone be kept an appropriate distance away from flame du...

Страница 7: ...or emergency shut off and maintenance WARNING For electronic ignition models there must be an electrical shutoff wall switch or breaker on the exterior of the appliance or on adjacent structure to all...

Страница 8: ...or models that include electronic ignitions be sure to have a qualified electrician install proper power supply following all local codes 6 Inspect flex line s for punctures or breaks in line s 7 Make...

Страница 9: ...ze and extended use Ready to Finish Kits come with Fire Pit Vent Kit FPVK Vents do not come pre installed on Ready to Finish Fire Pit Vent Kits must be installed on site 19 Only use fire rated media g...

Страница 10: ...ng provided by inserting 1 2 x 2 Nipple into interior threads of the Flared Fitting Tighten Then connect the 1 2 x 2 Nipple fitting into the coupling located on the bottom of the aluminum plate Tighte...

Страница 11: ...Flex Line to the Flared Fitting that is now connected to the Key Valve Connect Escutcheon Plate to Key Valve through vessel wall Tighten Flared Fitting Coupling Flared Fitting Whistle Free Flex Line K...

Страница 12: ...ling Do not use the 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitting to 1 2 Coupling located on the bottom of the aluminum plate Then connect 3 4 Tee to 1 2 x 3 4 Reducing Fitti...

Страница 13: ...Fittings connected to the aluminum plate and Coupling Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall T...

Страница 14: ...ey Valve 1 2 x 2 Nipple 12 Key STEP 1 FIT180 Whistle Free Flex Line Plate 3 Connect to Coupling FK1 Connect one 1 2 Flared Fitting removed in Step 2 to 1 2 x 2 Nipple fitting provided by inserting 1 2...

Страница 15: ...ND KEY VALVE FK1 Connect Whistle Free Flex Line to Flared Fitting connection at ignition and then to Key Valve connection in Step 5 Connect Escutcheon Plate to Key Valve through vessel wall Tighten 6...

Страница 16: ...le Free Flex Line 24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K 300K BTU Systems 3 Connect to Coupling FK2 Do not use 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitt...

Страница 17: ...LT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K 300K BTU SYSTEMS CONTINUED Plate Coupling 3 4 Tee Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 1 2 x 3 4 Reducing F...

Страница 18: ...onnect ends of 3 4 Whistle Free Flex Lines to Flared Fittings connected to the 24 Volt Ignition Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheo...

Страница 19: ...g needle nose pliers Be careful not to break connectors Wires can go in either connection Push Button Module Spark Igniter Wires Key Valve Mounting Bracket Jet Drill Here Spark Igniter Stem 125 Plate...

Страница 20: ...desired flame pattern For electronic ignition systems do not block cover or obstruct pilot assembly Blocking covering or placing ceramic logs too close to pilot may cause excessive heat on pilot causi...

Страница 21: ...al injury or death 3 Confirm that your Natural Gas or Liquid Propane sup ply to the appliance is open or on 4 Before lighting visually inspect fire feature and remove any accumulated leaves or other c...

Страница 22: ...debris 5 Locate key valve or gas control valve controlling gas supply to your appliance 6 Locate the jet tip nearest the lighting opening described above that can be easily accessed while operating k...

Страница 23: ...thout sharp bends and installed correctly Check the pressure to be sure it is within recommended ranges Contact a certified gas technician for service and re pair if these suggestions do not solve the...

Страница 24: ...s for the Burners without charge If a Burner does not function as warranted during the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2...

Страница 25: ...ifor nia to cause cancer or reproductive toxicity go to https oehha ca gov proposition 65 proposition 65 list Warnings Lead Can cause birth defects or other reproductive harm Lead can be found in bras...

Страница 26: ...x Lines 3 4 Key Valve 3 and 12 Key 1 3 4 x 1 2 MM Reducer Fitting and 1 3 4 Tee for connection at 1 2 Plate Coupling 1 3 4 x 3 Nipple and 1 3 4 Tee for Key Valve connection DFLKV34FIT300 2x 3 4 Flex L...