Warming Trends CFBL170 NG Скачать руководство пользователя страница 20

www.Warming-Trends.com  |  303 346 2224  |  [email protected]

20

MEDIA INSTALLATION

Only use approved decorative media (glass, lava rock, 

ceramic log sets, etc.) that have been manufactured for 

specific use in fire features.  
Media must be ½" or larger in size to prevent media from 

falling into gas orifices and blocking flow of gas out of 

jets. Use approved media only. To avoid dust and clogs get-

ting into the system, do not dump the media over the burner. 

Place the media onto the plate or pan. 
Burner should be covered by approved media up to 1/2” 

above the jets. Media may be positioned so that jet tips or 

barrels are visible. PLEASE NOTE - covering jets by more 

than 1/2" of media may create back pressure and gas 

leakage resulting in pooling of gas under the fire feature 

which can result in explosion which could cause proper-

ty damage, personal injury, or death. Also note that flame 

pattern will be affected by any media coverage over gas 

orifice jets up to and including smothering of flames. 
When using electronic ignition systems please pay par-

ticular attention to keeping media away from the pilot 

assembly area and/or away from wind screen of pilot 

assembly. Incorrect media installation that blocks pilot 

assembly will cause the pilot flame to stifle, blocking of 

thermal sensor and/or a delay in main burner ignition. 
The appliance is designed to use approved media that is 

correctly installed over the burner to achieve proper com-

bustion. Use of any media outside of the approved media 

may void warranty and affect proper operations.

Install enclosure and fire 

feature per instructions 

provided by manufacturer. 

DO NOT DUMP MEDIA 

ON THE JETS. Apply media 

by pouring media around 

burner first, then pushing 

media towards the gas jet 

orifices making sure media 

does not fall into the gas jet 

orifices. Check each gas jet 

orifice prior to lighting to be sure no media has fallen into 

gas jet orifices.  

For All Electronic Ignition Systems: Keep pilot assembly 

screen free and clear of all media. Media should be piled no 

more than halfway up screen only (not over full amount of 

screen) so that pilot gas orifice opening is above media cov-

erage allowing for pilot flame to easily reach gas jet orifice.

For Ceramic Log Sets: 

Place logs on top of lava 

rock or media base ac-

cording to preference and 

desired flame pattern.  For 

electronic ignition systems 

— do not block, cover or 

obstruct pilot assembly. 

Blocking, covering or placing ceramic logs too close to 

pilot may cause excessive heat on pilot causing system to 

fail. This is not covered under warranty.

OPERATING INSTRUCTIONS

Keep the area clear and free from combustible materials, 

gasoline, and other flammable vapors and liquids.
Solid fuels shall not be burned in the fire pit. Leaves, sticks, 

wood, paper, clothing, food material, should be kept away 

from the fire pit. Make sure that there is no vegetation or 

other objects over the top or sides of the fire pit that could 

interfere with safe operation. If there are any questions as 

to clearances, refer to CLEARANCES DIAGRAM in your 

Installation Manual for specific clearance allowances. 
Wind and gusty conditions may cause the flame to  

behave in an unpredictable manner. If conditions exist, 

turn off the fire feature.
All media (lava rock, volcanic stone, fire glass, etc.) has 

the potential of thermal spalling. This process may occur 

when media is wet and moisture gets trapped inside of 

the material due to rapid temperature differences. When 

this happens the media has the potential to crack or pop 

outside of the fireplace. Extra caution should be taken 

when lighting in high humidity or moisture. After igniting, 

allow 30 minutes to dry out the media, and monitor from 

a distance until all popping has ceased before fully enjoy-

ing the fire.
TURNING ON YOUR MATCH LIT SYSTEM 

1.  STOP! Read all the safety information.

2.  Any cover must be removed prior to operation of burn-

er or appliance and must remain off during operation. 

Danger: Fire or Explosion Hazard. If you smell gas, 

shut off gas to the appliance, extinguish any open 

flame. If odor continues, leave the area immedi-

ately. After leaving the area, call your gas supplier 

or fire department. Failure to follow these instruc-

tions could result in fire or explosion, which could 

cause property damage, personal injury or death.

3.  Confirm that your main Natural Gas or Liquid Propane 

supply to the appliance is open. Do not open your 

key valve or gas control valve at this time.

4.  Before lighting, visually inspect fire feature and remove 

any accumulated leaves or other combustible debris.

5.  Locate key valve or gas control valve controlling gas 

supply to your appliance.

6.  Locate the closest jet tip on the exterior of the burner 

that can be easily accessed while operating key valve 

or gas control valve without reaching across other jets 

or the burner.

Содержание CFBL170 NG

Страница 1: ...nformation for the safe installation and operation of your Warming Trends fire feature You must read this manual in its entirety prior to installation and or operation Failure to follow these instruct...

Страница 2: ...t Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and l...

Страница 3: ...un incendie ou une explosion pouvant causer des dommages mat riels des blessures ou la mort AVERTISSEMENT Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans...

Страница 4: ...NG LP with 24VIKSC Model CFBL190 NG LP with 24VIKSC Model CFB60 2XL NG LP with 24VIKSC Model CFBH120 NG LP with 24VIKSC Model CFBH160 NG LP with 24VIKSC Model CFBH200 NG LP with 24VIKSC Model CFBT110...

Страница 5: ...s not responsible for damage due to improperly installed or operated units Installers must leave this manual with the end user Instructions are updated as needed and it is the installer or owners resp...

Страница 6: ...st be located far enough away that there is no risk of ignition IMPORTANT It is recommended that material such as granite marble or other dense stone be kept an appropriate distance away from flame du...

Страница 7: ...or emergency shut off and maintenance WARNING For electronic ignition models there must be an electrical shutoff wall switch or breaker on the exterior of the appliance or on adjacent structure to all...

Страница 8: ...or models that include electronic ignitions be sure to have a qualified electrician install proper power supply following all local codes 6 Inspect flex line s for punctures or breaks in line s 7 Make...

Страница 9: ...ze and extended use Ready to Finish Kits come with Fire Pit Vent Kit FPVK Vents do not come pre installed on Ready to Finish Fire Pit Vent Kits must be installed on site 19 Only use fire rated media g...

Страница 10: ...ng provided by inserting 1 2 x 2 Nipple into interior threads of the Flared Fitting Tighten Then connect the 1 2 x 2 Nipple fitting into the coupling located on the bottom of the aluminum plate Tighte...

Страница 11: ...Flex Line to the Flared Fitting that is now connected to the Key Valve Connect Escutcheon Plate to Key Valve through vessel wall Tighten Flared Fitting Coupling Flared Fitting Whistle Free Flex Line K...

Страница 12: ...ling Do not use the 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitting to 1 2 Coupling located on the bottom of the aluminum plate Then connect 3 4 Tee to 1 2 x 3 4 Reducing Fitti...

Страница 13: ...Fittings connected to the aluminum plate and Coupling Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall T...

Страница 14: ...ey Valve 1 2 x 2 Nipple 12 Key STEP 1 FIT180 Whistle Free Flex Line Plate 3 Connect to Coupling FK1 Connect one 1 2 Flared Fitting removed in Step 2 to 1 2 x 2 Nipple fitting provided by inserting 1 2...

Страница 15: ...ND KEY VALVE FK1 Connect Whistle Free Flex Line to Flared Fitting connection at ignition and then to Key Valve connection in Step 5 Connect Escutcheon Plate to Key Valve through vessel wall Tighten 6...

Страница 16: ...le Free Flex Line 24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K 300K BTU Systems 3 Connect to Coupling FK2 Do not use 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitt...

Страница 17: ...LT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K 300K BTU SYSTEMS CONTINUED Plate Coupling 3 4 Tee Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 1 2 x 3 4 Reducing F...

Страница 18: ...onnect ends of 3 4 Whistle Free Flex Lines to Flared Fittings connected to the 24 Volt Ignition Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheo...

Страница 19: ...g needle nose pliers Be careful not to break connectors Wires can go in either connection Push Button Module Spark Igniter Wires Key Valve Mounting Bracket Jet Drill Here Spark Igniter Stem 125 Plate...

Страница 20: ...desired flame pattern For electronic ignition systems do not block cover or obstruct pilot assembly Blocking covering or placing ceramic logs too close to pilot may cause excessive heat on pilot causi...

Страница 21: ...al injury or death 3 Confirm that your Natural Gas or Liquid Propane sup ply to the appliance is open or on 4 Before lighting visually inspect fire feature and remove any accumulated leaves or other c...

Страница 22: ...debris 5 Locate key valve or gas control valve controlling gas supply to your appliance 6 Locate the jet tip nearest the lighting opening described above that can be easily accessed while operating k...

Страница 23: ...thout sharp bends and installed correctly Check the pressure to be sure it is within recommended ranges Contact a certified gas technician for service and re pair if these suggestions do not solve the...

Страница 24: ...s for the Burners without charge If a Burner does not function as warranted during the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2...

Страница 25: ...ifor nia to cause cancer or reproductive toxicity go to https oehha ca gov proposition 65 proposition 65 list Warnings Lead Can cause birth defects or other reproductive harm Lead can be found in bras...

Страница 26: ...x Lines 3 4 Key Valve 3 and 12 Key 1 3 4 x 1 2 MM Reducer Fitting and 1 3 4 Tee for connection at 1 2 Plate Coupling 1 3 4 x 3 Nipple and 1 3 4 Tee for Key Valve connection DFLKV34FIT300 2x 3 4 Flex L...