GENERAL MAINTENANCE

Any guard or protective device removed for servicing 

must be replaced prior to operating the appliance. 
Installation and repair should be done by a qualified tech-

nician. Appliances should be inspected prior to each use 

and inspected at least once annually by a qualified gas 

appliance service professional. 
Ensure gas and power (if applicable) are shut off and 

fire pit is cool before servicing. 
Keep fire feature covered at all times when not in use. 
Keep any debris out of appliance — clean as needed. If 

debris is found, remove before lighting system.

WARNING:

Fire feature should be inspected by user 

prior to each use and inspected at least 

once annually by a qualified gas appliance 

service professional. 

ever handling gas log.

Once your approved media has been installed, place 

your FireStorm

TM

 Steel Gas Log over the burner so that 

the burner is centered underneath it. Your steel log has 

a “lighting opening” at each end to aid in lighting the 

burner. (See Figure 1 below). Orient the steel log so that 

one end of the log is near the key valve. Press down upon 

the log to seat the log in the media to create a level and 

stable foundation. Adjust media as necessary.

Adjust your media so that the tip of the jet nearest the end 

of the log to be used for lighting is exposed. Use this jet 

for lighting the burner pursuant to Steps 6 and 7 below.

LIGHTING AND TURNING OFF YOUR MATCH LIT 

FIRESTORM STEEL GAS LOG SYSTEM

These instructions supplement the Lighting Instructions 

within your Owner’s Manual related to Turning On Your 

Match Lit System. Light your FireStorm Steel Gas Log 

using a “lighting opening” to access your burner as de-

scribed below.   
TURNING ON YOUR MATCH LIT SYSTEM 

1.  STOP! Read all the safety information. 

2.  Any cover must be removed prior to operation of 

burner or appliance and must remain off during 

operation. Danger: Fire or Explosion Hazard. If you 

smell gas, shut off gas to the appliance, extin-

guish any open flame. If odor continues, leave the 

area immediately. After leaving the area, call your 

gas supplier or fire department. Failure to follow 

these instructions could result in fire or explosion, 

which could cause property damage, personal 

injury or death. 

3.  Confirm that your main Natural Gas or Liquid Pro-

pane supply to the appliance is open. Do not open 

your key valve or gas control at this time.

4.  Before lighting, visually inspect fire feature and re-

move any accumulated leaves or other combustible 

debris. 

5.  Locate key valve or gas control valve controlling gas 

supply to your appliance. 

6.  Locate the jet tip nearest the “lighting opening” 

described above that can be easily accessed while 

operating key valve or gas control without reaching 

across other jets or the burner.  Reorient burner if 

necessary to allow such access. 

7.  Place a long reach lighter through the “lighting 

opening” of the gas log slightly above or on the tip of 

the jet located in Step 6 above. (See Figure 1). Do not 

use a match or cigarette lighter.

8.  While holding the flame on or slightly above the jet 

tip as described in Step 7 above, slowly turn the key 

valve or gas control knob slightly to the left to allow 

a minimal flow of gas to the burner and light the 

selected jet. While attempting to light jet, do not sub-

stantially increase gas supply. Excessive flow of gas 

before jet is lit can cause pooling of gas and result in 

sudden flare up. Failure to follow these instructions 

could result in fire or explosion, which could cause 

property damage, personal injury or death. 

9.  Once the selected jet (or other jets) is lit, continue to 

keep any body parts from above the pit or burner and 

slowly turn the key valve or gas control knob further to 

the left to increase the flow of gas to the burner. The 

other jets of the burner should ignite. 

10.  If the flame will not stay lit after several attempts, turn 

the key valve or gas control to the off position and call 

your local technician or gas supplier for service prior 

to re-attempting to operate your appliance. 

11.  Once lit, use the key valve or gas control to adjust the 

flame to the desired height. 

TURNING OFF YOUR MATCH LIT BURNER

1.  Use key to turn valve to OFF position by turning the 

valve to the right. 

2.  Verify flame is OUT. 

3.  If using LP bottle/tank, turn bottle/tank to CLOSED 

position. 

4.  Allow to cool completely, then cover the fire feature 

with waterproof/weatherproof cover. 

APPEARANCE

Your steel log should patina over time by forming a layer 

of rust or oxidation. The coloring may change and the log 

will look more natural. Each log develops a unique patina 

pattern based upon use and weather conditions. Heat will 

also create distinctive color changes to your log’s surface. 
CLEANING STEEL LOG

Soot may build up along the openings in the log or on its 

surface in general. Annual cleaning is recommended. How-

ever, if soot restricts or reduces normal flame performance, 

clean openings immediately. Prior to any cleaning or han-

dling, wait for log to cool completely and then remove 

the log from the system. Soot is then easily removed by 

spraying the log with water or by lightly brushing with a 

plastic brush. Do not allow water or soot to fall into burner 

system.

Lighting Opening

Содержание CFBL170 NG

Страница 1: ...nformation for the safe installation and operation of your Warming Trends fire feature You must read this manual in its entirety prior to installation and or operation Failure to follow these instruct...

Страница 2: ...t Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death WARNING Do not store or use gasoline or other flammable vapors and l...

Страница 3: ...un incendie ou une explosion pouvant causer des dommages mat riels des blessures ou la mort AVERTISSEMENT Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans...

Страница 4: ...NG LP with 24VIKSC Model CFBL190 NG LP with 24VIKSC Model CFB60 2XL NG LP with 24VIKSC Model CFBH120 NG LP with 24VIKSC Model CFBH160 NG LP with 24VIKSC Model CFBH200 NG LP with 24VIKSC Model CFBT110...

Страница 5: ...s not responsible for damage due to improperly installed or operated units Installers must leave this manual with the end user Instructions are updated as needed and it is the installer or owners resp...

Страница 6: ...st be located far enough away that there is no risk of ignition IMPORTANT It is recommended that material such as granite marble or other dense stone be kept an appropriate distance away from flame du...

Страница 7: ...or emergency shut off and maintenance WARNING For electronic ignition models there must be an electrical shutoff wall switch or breaker on the exterior of the appliance or on adjacent structure to all...

Страница 8: ...or models that include electronic ignitions be sure to have a qualified electrician install proper power supply following all local codes 6 Inspect flex line s for punctures or breaks in line s 7 Make...

Страница 9: ...ze and extended use Ready to Finish Kits come with Fire Pit Vent Kit FPVK Vents do not come pre installed on Ready to Finish Fire Pit Vent Kits must be installed on site 19 Only use fire rated media g...

Страница 10: ...ng provided by inserting 1 2 x 2 Nipple into interior threads of the Flared Fitting Tighten Then connect the 1 2 x 2 Nipple fitting into the coupling located on the bottom of the aluminum plate Tighte...

Страница 11: ...Flex Line to the Flared Fitting that is now connected to the Key Valve Connect Escutcheon Plate to Key Valve through vessel wall Tighten Flared Fitting Coupling Flared Fitting Whistle Free Flex Line K...

Страница 12: ...ling Do not use the 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitting to 1 2 Coupling located on the bottom of the aluminum plate Then connect 3 4 Tee to 1 2 x 3 4 Reducing Fitti...

Страница 13: ...Fittings connected to the aluminum plate and Coupling Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheon Plate to Key Valve through vessel wall T...

Страница 14: ...ey Valve 1 2 x 2 Nipple 12 Key STEP 1 FIT180 Whistle Free Flex Line Plate 3 Connect to Coupling FK1 Connect one 1 2 Flared Fitting removed in Step 2 to 1 2 x 2 Nipple fitting provided by inserting 1 2...

Страница 15: ...ND KEY VALVE FK1 Connect Whistle Free Flex Line to Flared Fitting connection at ignition and then to Key Valve connection in Step 5 Connect Escutcheon Plate to Key Valve through vessel wall Tighten 6...

Страница 16: ...le Free Flex Line 24 VOLT ELECTRONIC IGNITION SYSTEM CONNECTION DIAGRAMS 250K 300K BTU Systems 3 Connect to Coupling FK2 Do not use 2nd 3 4 x 3 Nipple with this install Connect 1 2 x 3 4 Reducing Fitt...

Страница 17: ...LT ELECTRONIC IGNITION SYSTEM INSTALLATION 250K 300K BTU SYSTEMS CONTINUED Plate Coupling 3 4 Tee Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 1 2 x 3 4 Reducing F...

Страница 18: ...onnect ends of 3 4 Whistle Free Flex Lines to Flared Fittings connected to the 24 Volt Ignition Then connect available ends of the Whistle Free Flex Lines to the Key Valve Connection Connect Escutcheo...

Страница 19: ...g needle nose pliers Be careful not to break connectors Wires can go in either connection Push Button Module Spark Igniter Wires Key Valve Mounting Bracket Jet Drill Here Spark Igniter Stem 125 Plate...

Страница 20: ...desired flame pattern For electronic ignition systems do not block cover or obstruct pilot assembly Blocking covering or placing ceramic logs too close to pilot may cause excessive heat on pilot causi...

Страница 21: ...al injury or death 3 Confirm that your Natural Gas or Liquid Propane sup ply to the appliance is open or on 4 Before lighting visually inspect fire feature and remove any accumulated leaves or other c...

Страница 22: ...debris 5 Locate key valve or gas control valve controlling gas supply to your appliance 6 Locate the jet tip nearest the lighting opening described above that can be easily accessed while operating k...

Страница 23: ...thout sharp bends and installed correctly Check the pressure to be sure it is within recommended ranges Contact a certified gas technician for service and re pair if these suggestions do not solve the...

Страница 24: ...s for the Burners without charge If a Burner does not function as warranted during the Warranty Period and after a reasonable number of attempts WARMING TRENDS is unable to either 1 make it do so or 2...

Страница 25: ...ifor nia to cause cancer or reproductive toxicity go to https oehha ca gov proposition 65 proposition 65 list Warnings Lead Can cause birth defects or other reproductive harm Lead can be found in bras...

Страница 26: ...x Lines 3 4 Key Valve 3 and 12 Key 1 3 4 x 1 2 MM Reducer Fitting and 1 3 4 Tee for connection at 1 2 Plate Coupling 1 3 4 x 3 Nipple and 1 3 4 Tee for Key Valve connection DFLKV34FIT300 2x 3 4 Flex L...

Отзывы: