background image

10

warmhaus.com

2.4. SOLUTIONS FOR MALFUNCTIONS AND ERRORS

Malfunction/

Error Code

Malfunction/Error Code 

Description

Water Heater Status

Possible Causes

Solution

E 04

Hot Domestic Water 

temperature sensor error

Device is not functioning 

and E04 malfunction 

code is flashing on the 

screen

Hot Domestic Water 

temperature sensor error

1-) Reset 

 / restart the device and check if the malfunction 

is resolved.

2-) If the malfunction persists, call the Authorized Service.

E 05

Hot Domestic Water 

temperature (Safety) 

sensor error

Device is not functioning 

and E05 malfunction 

code is flashing on the 

screen

Hot Domestic Water 

temperature (Safety) 

sensor error

1-) Reset 

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

E 06

No ignition

Device is not functioning 

and E06 malfunction 

code is flashing on the 

screen

Gas supply failure

1-) Reset 

 / restart the device and check if the malfunction 

is resolved.

2-) Check if other gas devices are working. 3-) Check if the main 

gas valve is open.

4-) Check if the device gas valve under the device is open or not.
5-) Reset 

 / restart the device and check if the malfunction 

is resolved.

6-) If the malfunction persists, call the Authorized Service.

E 07

Security/Safety 

Thermostat intervention

Device is not functioning 

and E07 malfunction code 

is flashing on the screen

Low water flow rate

Clogged installation

1-) Reset 

 / restart the device and check if the problem is 

solved.

2-) Check the water flow

2-) If the problem is not solved, call the authorized service.

E 08

Flame circuit 

malfunction

Incorrect flame signal 

from electrode or 

combustion

Wear or rust on the 

electrode

Electrode position

Broken wiring

Electronic card

1-) Reset 

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

E 09

No water circulation in 

the system

Device is not functioning 

and E09 malfunction 

code is flashing on the 

screen

Lack of water in the 

system

Clogged installation

1-) Reset 

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

E 11

Gas valve modulator not 

connected

Device is not functioning 

and E11 malfunction code 

is flashing on the screen

Gas line malfunction

1-) Reset 

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

E 15

Fan malfunction 

(feedback/ supply)

device is not functioning 

and E15 malfunction code 

is flashing on the screen

Fan cable

1-) Reset 

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

E 17

Temperature difference 

between FLOW and 

LIMIT NTC (Dual Heating 

sensor) faulty

Device is not functioning 

and E17 malfunction code 

is flashing on the screen

FLOW and LIMIT SENSOR

(dual NTC) faulty

1-) Reset 

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

E 20

Heater Over-

temperature 

Malfunction, Heater 

Heating Temperature 

exceeded TSP 81 °C set 

value

Device is not functioning 

and E20 malfunction 

code is flashing on the 

screen

Lack of water in the 

system

Clogged installation

1-) Reset 

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

E 37

At low voltage

Device is not functioning 

and E37 malfunction code 

is flashing on the screen

Low voltage < 165 VAC 

+/- 5% in mains operation 

mode OR <182 VAC 

+/- 5% in automatic 

calibration mode

1-) Reset  

 / restart the device.

2-) If the malfunction persists, call the Authorized Service.

Содержание AQUWA 12

Страница 1: ...GAS FUELED HERMETIC WATER HEATER USER MANUAL AQUWA 12...

Страница 2: ...AquWa 12...

Страница 3: ...Risk of Getting Injured by Flue Pipes 6 2 USER SECTION 8 2 1 GENERAL WARNINGS FOR USER 8 2 2 USE OF WATER HEATER 8 2 2 1 Control Panel and its Functions 8 2 2 2 Turning On Off of Water Heater and Temp...

Страница 4: ...and application for LPG use should be performed by the company supplying the tank according to the local and legal rules 1 2 GENERAL WARRANTY CONDITIONS The manufacturer company shall not have any re...

Страница 5: ...us service technician at least once a year Failure to follow these instructions may result in serious possibly fatal personal injury and also property and equipment damage It is strictly forbidden to...

Страница 6: ...on and Maintenance Maintenance and repairs may be carried out only by a trained and certified Warmhaus service Correct any installation errors immediately to avoid damage to the system 1 3 6 Electrica...

Страница 7: ...7 warmhaus com...

Страница 8: ...ls while it is running Do not hold the heater with your hands or feet wet do not hold it without shoes and in bare feet Do not pull the electrical cables In case of damage to the cables turn off the w...

Страница 9: ...Their Descriptions E 06 Lockout indicator Wiring error E 08 Ignition Combustion error indicator E 07 High limit protection E 41 Loss of flame 6 times in 10 minutes E 88 Gas valve operation malfunctio...

Страница 10: ...from electrode or combustion Wear or rust on the electrode Electrode position Broken wiring Electronic card 1 Reset restart the device 2 If the malfunction persists call the Authorized Service E 09 N...

Страница 11: ...1 Initial combustion lockout blocking problem Device is not functioning and E81 malfunction code is flashing on the screen Excessive blockage in the flue Combustion problem Incorrect flue Gas inlet pr...

Страница 12: ...umption maximum m3 h 2 43 0 959 Nozzles 85 50 NOx Grade 6 6 NOx mg kWh 37 7 26 Hot water Load profile Load Profile L Seasonal Efficiency 77 Seasonal Efficiency Class Grade A Minimum Water Flow min 3 M...

Страница 13: ...13 warmhaus com...

Страница 14: ......

Страница 15: ...been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject...

Страница 16: ...AQUWA 12 User Manual 15011606000133 Revision Number Date R00 09 2021 GAS FUELED HERMETIC WATER HEATER USER MANUAL AQUWA 12...

Отзывы: