background image

12

warmhaus.com

3.  TECHNICAL DATA

TECHNICAL DATA

UNIT

WARMHAUS

AquWa 12

Gas type

G20

G31

Gas Supply Pressure

mbar

20

37

Gas Category

G20

I

2H

  I

2H 

, I

2E 

, I

2E(S) 

, I

3P 

, I

I2E3P 

, I

I2E(S)3P 

, I

I2H3P 

, I

I2E+3P

Rated Heat Load (Minimum)

kW

10.0

10

Rated Heat Load (Maximum)

kW

23.5

23.5

Rated Heat Power (Minimum)

kW

8.90

8.95

Rated Heat Power (Maximum)

kW

20.7

20.6

Efficiency (Minimum)

%

89.2

89.5

Efficiency (Maximum)

%

88.1

87.62

Gas Consumption (minimum)

m3/h

1.03

0,4

Gas Consumption (maximum)

m3/h

2.43

0.959

Nozzles

85

50

NOx

Grade

6

6

NOx

mg/kWh

37.7

26

Hot water Load profile

Load Profile

L

Seasonal Efficiency

%

77

Seasonal Efficiency Class

Grade

A

Minimum Water Flow

l/min.

3

Maximum Water Capacity (ΔT=25 °C)

l/min.

12

Sound Level

dB

48

Water Pressure (max.)

bar

10

Water Pressure (min.)

bar

0.5

Setting Range

0

C

35-60

Power Supply

V AC

230 V +10%;-15%, 50 Hz

Electrical Protection Class

IPX4D

Electric Consumption

W

20 - 30

Waste Gas Temperature (min.-max.)

0

C

110 - 190

Flue type

C12, C32 C42, C52, C62, C82, B22, B22P

Flue mass flow rate (min./max)

g/s

9 / 13

Dimensions

mm

638 x 336 x 242

Volume of Device

Liter

51.9

Weight, Net

kg

15

Weight, Gross

kg

17

Содержание AQUWA 12

Страница 1: ...GAS FUELED HERMETIC WATER HEATER USER MANUAL AQUWA 12...

Страница 2: ...AquWa 12...

Страница 3: ...Risk of Getting Injured by Flue Pipes 6 2 USER SECTION 8 2 1 GENERAL WARNINGS FOR USER 8 2 2 USE OF WATER HEATER 8 2 2 1 Control Panel and its Functions 8 2 2 2 Turning On Off of Water Heater and Temp...

Страница 4: ...and application for LPG use should be performed by the company supplying the tank according to the local and legal rules 1 2 GENERAL WARRANTY CONDITIONS The manufacturer company shall not have any re...

Страница 5: ...us service technician at least once a year Failure to follow these instructions may result in serious possibly fatal personal injury and also property and equipment damage It is strictly forbidden to...

Страница 6: ...on and Maintenance Maintenance and repairs may be carried out only by a trained and certified Warmhaus service Correct any installation errors immediately to avoid damage to the system 1 3 6 Electrica...

Страница 7: ...7 warmhaus com...

Страница 8: ...ls while it is running Do not hold the heater with your hands or feet wet do not hold it without shoes and in bare feet Do not pull the electrical cables In case of damage to the cables turn off the w...

Страница 9: ...Their Descriptions E 06 Lockout indicator Wiring error E 08 Ignition Combustion error indicator E 07 High limit protection E 41 Loss of flame 6 times in 10 minutes E 88 Gas valve operation malfunctio...

Страница 10: ...from electrode or combustion Wear or rust on the electrode Electrode position Broken wiring Electronic card 1 Reset restart the device 2 If the malfunction persists call the Authorized Service E 09 N...

Страница 11: ...1 Initial combustion lockout blocking problem Device is not functioning and E81 malfunction code is flashing on the screen Excessive blockage in the flue Combustion problem Incorrect flue Gas inlet pr...

Страница 12: ...umption maximum m3 h 2 43 0 959 Nozzles 85 50 NOx Grade 6 6 NOx mg kWh 37 7 26 Hot water Load profile Load Profile L Seasonal Efficiency 77 Seasonal Efficiency Class Grade A Minimum Water Flow min 3 M...

Страница 13: ...13 warmhaus com...

Страница 14: ......

Страница 15: ...been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject...

Страница 16: ...AQUWA 12 User Manual 15011606000133 Revision Number Date R00 09 2021 GAS FUELED HERMETIC WATER HEATER USER MANUAL AQUWA 12...

Отзывы: