TECHNICAL CHARACTERISTCS
TR05A140.B1107
14
3.6.3 Function codes
Code
Function
Description
07
Commissioning Mode
Operates the boiler at maximum CH output for 15 minutes
without modulation.
Activated by pressing and holding the
S
button for 7 seconds.
Deactivated by switching the appliance off.
08
CH Frost Protection Mode
Operates the boiler at minimum CH output in Heating Only
Mode.
Activated when the CH sensor detects below 5°C.
Deactivated when the CH sensor detects above 30°C.
Table 4: Function codes