Function

Momentary-contact switches or latched switches can be 

used as floor operating elements. The move commands 

of the floor switches are passed on directly to the motor 

control units.
The operating elements may not be jumpered. 

For the use of momentary contact switches as floor 

switches this means:

 

 

The operator has to press the floor momentary-contact 

switch until the sunblinds of the controlled facade have 

reached the desired position.

 

 

A move command from a higher-level central control 

takes precedence over the floor momentary-contact 

switch. 

For the use of latched switches as floor switches this 

means: 

 

 

The operator presses the floor latched switch and 

moves away from the operating point. The sunblinds 

move UP or DOWN to the end position.

 

 

A move command from a higher-level central control 

takes precedence over the floor latched switch. The 

sunblinds move in the direction specified by the central 

control exactly as long as the central command remains 

active. Afterwards the sunblinds move again into the 

end position specified by the latched floor switch.

 

 

When the floor latched switches are latched, the local 

switches of the motor control unit are blocked

Commissioning

The device is ready for operation after the installation has 

been completed and the operating voltage applied.

Maintenance

There are no parts within the device that require mainte-

nance. In the event of a malfunction, the installed miniature 

fuse may only be exchanged by a certified electrician.

Cleaning

Clean the housing with a soft, dry cloth. Do not use deter-

gents, cleaning agents, solvents, abrasive substances or 

steam cleaners! 

Liability

Failure to comply with the product information contained in 

these instructions and any use of the device other than its 

intended use and purpose may result in the manufacturer 

refusing to honour warranty claims for product damage. In 

this case, liability for consequential damage to persons or 

property will also be excluded. Also observe the informa-

tion in the operating instructions for your sun shading 

system. The automatic or manual operation of the sun 

shading system when iced over as well as using the sun 

shading system during severe weather may cause dam-

age and must be prevented by the user through suitable 

precautions.

Obligations for the disposal of electrical devices 

A marking with this symbol indicates the following 

obligations under the scope of legal regulations: 

 

 

The owner of this electrical device must dispose of it 

separately from unsorted municipal waste for further 

recycling.

 

 

Used batteries and accumulators that are not enclosed 

in the old device, as well as lamps/bulbs that can be 

removed from the old device without breaking, must be 

disposed of separately.

 

 

Distributors of electrical devices and disposal companies 

are obliged to take back the equipment free of charge.

 

 

The owner must take it upon themselves to delete any 

personal data contained in the electrical device prior to 

disposal.

Technical data

GA Standard

min.

typ.

max.

Unit

Supply 230 V AC

operating voltage

207

230

253

V AC

power consumption

5

80

VA

Output

Control voltage

22

29

32

V DC

Current  

(all 4 facades) 

2

A

Input (central / local)

Input voltage inactive

0

0

2

V DC

Input voltage active

17

24

32

V DC

Input current active

13

mA

Housing

Dimensions L x W x H

240 x 160 x 90 mm

degree of protection

IP 54

Connection

All connections

screw terminals

Connection terminals

supply line

0,5...1,5 mm

2

control line,

push button line

0,5...1,5 mm

2

Miscellaneous

Conformity

can be viewed at 

 

www.warema.de/ce

This device complies with the EMC directives for use in re-

sidential and commercial areas.

Ambient conditions

Operating temperature

0

40

°C

Storage temperature

-25

75

°C

Humidity

(not condensing)

10

40

80

%H

rel

Degree of soiling

2

Article number

Floor distribution control 

Standard (GA) Standard 

for 4 facades

1002 253

WAREMA Renkhoff SE 

Hans-Wilhelm-Renkhhoff-Strasse 2 

97828 Marktheidenfeld, Germany