Maintenance—Schedule
T7M7G6M,0000462 -19-10JUN20-2/2
T7M7G6M,0000463 -19-10JUN20-1/1
IMPORTANT: Corrosion builds up on the
potentiometer sensor plates. Rotate the
potentiometer several revolutions in both
directions by hand. Corroded sensor plates
result in inaccurate diameter measurements..
7. Remove potentiometer (5). (See CTM for Diameter
Potentiometer Remove and Install).
8. Inspect diameter potentiometer and rotate
potentiometer shaft (6) several revolutions in both
directions by hand.
9. Inspect diameter potentiometer linkage.
5— Potentiometer
6— Potentiometer Shaft
TX1060903A
—UN—19JUN09
Maintenance—Every 2000 Hours or Yearly
SPECIFICATIONS
Ring to Tilt Frame Cap Screw
(1/2-in. UNF) Torque
171 N·m
126 lb-ft
CAUTION: Prevent possible injury while working
in the arm capture zones or saw bar opening.
Keep away from the arm capture zones or the
saw bar opening of the harvester head while the
hydraulic system is active. Failing to follow these
safety precautions may lead to serious injury.
1. Complete 6 month checks.
2. Check rotator ring to tilt frame cap screws. Torque cap
screws (1/2-in. UNF) to specification.
3. Check the condition of the delimb knives, feed arms,
links, pins,bushes, and main frame.
4. Inspect rotator pinion support for cracks.
4
2
1
3
3
2
TX1287137
—UN—24OCT19
1— Rotator Ring
2— Feed Arm
3— Delimb Knife
4— Rotator Pinion
3-2-8
053122
PN=70