Wantegrity HAWK-800 Скачать руководство пользователя страница 31

MIDI Hints and Tips

MIDI System Exclusive Messages

This section discusses the details of using original EX-800 and Poly-800 Mk2 MIDI system exclusive bulk data dump 

messages with the HAWK-800. Refer to the MIDI implementation chart for details on the many other MIDI system 
exclusive messages that the HAWK-800 recognizes and supports.

Receiving EX-800 or Poly-800 Mk2 Sysex Bulk Data

Receiving EX-800 and MK2 sysex bulk patch dumps is handled by Tools mode 8. See “Tools” mode function 8 later in this 
document.

MIDI Controller Messages

This section discusses the details of using MIDI controller messages to change parameters in a running patch. Refer to the 
MIDI implementation chart for details on the many other MIDI controller messages that the HAWK-800 recognizes and 
supports. There are three different ways in which you can control the parameters in the HAWK-800 using MIDI controller 
(CC) messages. We discuss each method below. See the MIDI implementation chart for additional information on the 
format of MIDI CC messages for the HAWK-800.

MIDI CC Non Registered Parameter Number Method

The first MIDI CC parameter change method conforms to the MIDI specification for controlling non registered parameter 
numbers (NRPN's). This method uses MIDI CC's 99 (NRPN MSB), 98 (NRPN LSB) and 6 (Data Value). The use this method, 
the MIDI CC messages would be sent in this order and format:

1) Send MIDI CC 99 with the data value matching global parameter 16. If the NRPN MSB does not match global parameter 
16 then the desired parameter will not be changed. This is useful if you have more than one HAWK-800 listening on the 
same MIDI channel and wish to edit sounds independently which can be done by setting global parameter 16 to be unique 
on each HAWK-800.
2) Send MIDI CC 98 with the data value set to select the desired target parameter where 00-63 matches parameters in the 
P1 bank (P1 11-88) and 64-127 matches the parameters in the P2 bank (P2 11-88).
3) Send MIDI CC 6 with the data value set to the desired value for the target parameter (but ranged to fit within 0-127). 
For each parameter, the data value sent should be in the range 0-127 and the HAWK-800 will automatically adjust the 
value to fit the parameter. So for example, DCO waveform is only 1-2 so the HAWK-800 would set 1 if the MIDI CC data 
value was from 0-63 and the HAWK-800 would set the waveform to 2 if the MIDI CC data was in the range 64-127.

MIDI CC “Quick Parameter Change” Method

The second MIDI CC parameter change method is a non standard method for quickly changing HAWK-800 parameters. It is 
similar to the NRPN method but uses two non standard MIDI CC's (84 and 85) instead of three as the NRPN method uses. 
This makes this MIDI controller parameter changing method more efficient. To use this method, the MIDI CC messages 
would be sent in this order and format:

1) Send MIDI CC 84 with the data value set to select the desired target parameter where 00-63 matches parameters in the 
P1 bank (P1 11-88) and 64-127 matches the parameters in the P2 bank (P2 11-88).
2) Send MIDI CC 85 with the data value set to the desired value for the target parameter (but ranged to fit within 0-127).

-31-

Содержание HAWK-800

Страница 1: ...1...

Страница 2: ...t Thank you and congratulations on your choice of the HAWK 800 upgrade kit This kit has been engineered for highest quality sounds and superb reliability To obtain optimum performance from your new HA...

Страница 3: ...ncer mode you can edit up to seven different sequences and each one can be selected to play in real time Sequences can be locked to protect them from accidental editing The sequencer edit display show...

Страница 4: ...SYSEX dump global parameters 10 11 GL 25 Jump into flash update routine 10 11 GL 26 Jump into diagnostics mode 10 Global Mode Parameters 10 12 GL xx Selected patch or parameter 10 13 GL xx Patch Bank...

Страница 5: ...meter Groups 16 P1 Parameters 11 18 21 27 17 P1 13 23 DCO harmonics selector 17 P1 14 24 DCO harmonics modulation waveform selector 17 P1 15 25 DCO harmonics modulation LFO selector 18 P1 16 26 DCO ha...

Страница 6: ...ation Group 24 P2 41 VCF 1st LFO waveform selector 24 P2 42 VCF 1st LFO modulation source selector 24 P2 43 VCF 1st LFO modulation depth 24 P2 44 VCF 2nd LFO waveform selector 24 P2 45 VCF 2nd LFO mod...

Страница 7: ...Hints and Tips 31 MIDI System Exclusive Messages 31 Receiving EX 800 or Poly 800 Mk2 Sysex Bulk Data 31 MIDI Controller Messages 31 MIDI CC Non Registered Parameter Number Method 31 MIDI CC Quick Para...

Страница 8: ...http www hawk800 com Finding Your Way Around Front Panel There are four major differences between the operation of the front panel buttons and the original Korg Poly 800 or EX 800 Poly 800 MK1 and MK2...

Страница 9: ...e HAWK 800 software 11 GL 11 No operation No command is executed if you select executable parameter 11 and set the data value to 11 and press the Write key This ensures that you don t accidentally exe...

Страница 10: ...he data display will be blanked out You edit global parameters by using the keypad to select the desired parameter and then using the up and down buttons to set the value for that global parameter The...

Страница 11: ...ogram Up 1 Pedal will hold notes at sustain level 2 Decay and Release will be extended by extended parameter 78 3 Both mode 1 and 2 combined The pedal jack on the rear of the Poly 800 was originally d...

Страница 12: ...annel 27 GL xx MIDI receive channel xx 1 16 Determines the MIDI receive channel to which the synthesizer will respond 28 GL xx MIDI soft thru xx 0 off 1 on This parameters allows setting the HAWK 800...

Страница 13: ...sages and the pitch of the unit itself will not work correctly if this parameter is not set to one If your HAWK 800 kit is installed in a Poly 800 MK2 then the device type should be set to 2 This enab...

Страница 14: ...t to off so that no transmission of joystick movement occurs 42 GL xx Local Joystick control off xx 0 off 1 on original 2 extended mode 3 extended mode with patch change Allows turning local control o...

Страница 15: ...he sequencer by reducing the number of ticks A typical use would be to set the tick count to 3 so that the sequencer would step forward twice as fast This is particularly useful for matching the time...

Страница 16: ...ons Remapped Original Parameters Certain parameter numbers have been changed to allow support of the MK2 effects parameters and to fit in additional parameters as efficiently as possible The HAWK 800...

Страница 17: ...harmonics on 16 all harmonics off Selects the DCO harmonics to be enabled at note onset If no harmonic modulation is applied then this parameter determines the DCO harmonics that will be applied thro...

Страница 18: ...ter 34 is set to 0 or 1 corresponding with Poly 800 MK1 or EX 800 then these parameters are inactive and will not be available for editing P1 34 MK2 Effects Unit Delay Time 00 99 sets the delay of the...

Страница 19: ...her bass When the Poly 800 device global parameter 34 is set to 2 then these parameters become active If global parameter 34 is set to 0 or 1 corresponding with Poly 800 MK1 or EX 800 then parameters...

Страница 20: ...er of the velocity operators are not being used then that operator or both should be disabled P1 82 85 OP1 OP2 Velocity Intensity Invert 0 1 0 normal intensity 1 inverted intensity Both velocity opera...

Страница 21: ...ues Both LFO s have seven identical parameter controls The eighth parameter is unique between the two LFO s We discuss each of the common parameters together and then discuss the unique parameters sep...

Страница 22: ...oth 4 inverted sawtooth 5 sine wave 6 inverted sine wave 7 square PWM wave 8 inverted square PWM wave It is now possible to modulate the frequency of LFO1 by SLFO3 and LFO2 by SLFO4 The SLFO waveform...

Страница 23: ...d hold from sequencer loop repeat point Selects the LFO waveform that will be used to modulate the DCO s P2 32 DCO LFO modulation source selector 1 4 1 LFO1 2 LFO2 3 SLFO3 4 SLFO4 Selects the LFO or S...

Страница 24: ...odulated by any of the four LFO s and the EG3 envelope generator P2 41 VCF 1st LFO waveform selector 1 8 1 triangle 2 inverted triangle 3 sawtooth 4 inverted sawtooth 5 sine wave 6 inverted sine wave...

Страница 25: ...use 12db per octace filter slope NOTE Only works with the aTomaHawk 800 upgrade kit Resonance Modulation Group The resonance of the VCF can now be modulated by any of the four LFO s and the EG3 envelo...

Страница 26: ...aTomaHawk 800 upgrade kit Selects the mode of operation of the resonance modulation Setting this parameter to zero applies the normal amount of modulation to the resonance level Setting this value to...

Страница 27: ...FM800 level Setting this parameter to zero will turn off all LFO modulation of FM800 Setting this parameter to 15 will apply the maximum possible modulation P2 66 FM800 EG depth 00 15 00 no EG modulat...

Страница 28: ...dom Sample and Hold Ticks 01 99 Number of note ticks to pass before next RSH from seq Or MIDI clock This setting determines how many quarter notes should pass before the next random sample is held for...

Страница 29: ...last four a unique per patch parameters P2 81 Tremolo DCO1 mode and LFO source 0 2 0 set tremolo on DCO1 off 1 use LFO1 as source for tremolo modulation 2 use LFO2 as source for tremolo modulation Use...

Страница 30: ...rameter that is found to contain data that is outside of the limits for that parameter will be reset to be exactly half of the allowed range for that parameter This means that the first time you power...

Страница 31: ...atch global parameter 16 then the desired parameter will not be changed This is useful if you have more than one HAWK 800 listening on the same MIDI channel and wish to edit sounds independently which...

Страница 32: ...cian will generally edit HAWK 800 sounds by working inside of each parameter group So it is very convenient to be able to set up a hardware controller to select a parameter group and then edit any one...

Страница 33: ...all global memory to zero except for the device type global parameter 34 which will retain its value It is important to ensure that the device type and all other parameters are set correctly Use this...

Страница 34: ...s functions Or press the the Bank Hold button to return to normal synthesizer operation Or press the Prog Para button to restart the HAWK 800 If the HAWK 800 displays an error code then consider the f...

Страница 35: ...86 and VCF velocity operator set by parameters P1 87 88 add additional delay between when a MIDI note on event is received by the Poly 800 and the actual onset of those notes Thus if you do not wish...

Страница 36: ...e if we had first selected sequence three as mentioned in point 3 above and then pressed and held the Write button while then pressing the sequencer Start button The display shows the selected patch w...

Страница 37: ...es playing and the new selected sequence begins to play A selected sequence will continue to loop until it is either stopped using the Start Stop button or another sequence is selected for playback 8...

Страница 38: ...ill change to show sequence 8 as being selected Sequence 8 is not stored in non volatile flash memory so you must copy the sequence to 1 thru 7 sequence locations if you wish to keep sequence 8 13 You...

Страница 39: ...synth to use seven segment displays Hold down the Start Stop button Switch to LCD display mode Not yet implemented Allows use of a standard 16 x 2 LCD display SourceForge HAWK800 Project Software dev...

Отзывы: