![Wantegrity HAWK-800 Скачать руководство пользователя страница 25](http://html2.mh-extra.com/html/wantegrity/hawk-800/hawk-800_owners-manual_3348516025.webp)
6=inverted sine wave
7=square PWM wave
8=inverted square PWM wave
9=random sample and hold
Selects the LFO waveform that will be used to modulate the VCF.
P2 45 – VCF 2
nd
LFO modulation source selector
1-4 – 1=LFO1, 2=LFO2, 3=SLFO3, 4=SLFO4
Selects the LFO or SLFO that will modulate the VCF.
P2 46 – VCF 2
nd
LFO modulation depth
00-15 – 00=no LFO modulation, 01-15 apply LFO modulation
Selects the amount of LFO modulation to apply to the VCF. Setting this parameter to zero will turn off all LFO modulation
of the VCF. Setting this parameter to 15 will apply the maximum possible modulation.
P2 48 – VCF 12/24db filter selector **
1-2 –
1=use 24db per octave filter slope
2=use 12db per octace filter slope
** NOTE: Only works with the aTomaHawk-800 upgrade kit.
Resonance Modulation Group
The resonance of the VCF can now be modulated by any of the four LFO's and the EG3 envelope generator.
P2 51 – Resonance set point
00-99 – 00-99 set the resonance level
Use this parameter to set the resonance level from zero to maximum (99).
NOTE: The original resonance parameter (P1 42) is no longer used and has been reused because the extended resonance
set point parameter (P2 51) provides much higher resolution and is more aggressive at higher resonance levels.
P2 52 – Resonance LFO modulation waveform selector
1-8 –
1=triangle
2=inverted triangle
3=sawtooth
4=inverted sawtooth
5=sine wave
6=inverted sine wave
7=square PWM wave
8=inverted square PWM wave
9=random sample and hold
Selects the LFO waveform that will be used to modulate resonance.
-25-
Содержание HAWK-800
Страница 1: ...1...