![Wantegrity HAWK-800 Скачать руководство пользователя страница 19](http://html2.mh-extra.com/html/wantegrity/hawk-800/hawk-800_owners-manual_3348516019.webp)
It is important to understand that keyboard tracking is OFF when velocity sensitive VCF is enabled. Refer to P1 parameters
87 and 88 for additional detail.
P1 43 – VCF EG3 Polarity
1-2 –
1=normal positive polarity
2=negative polarity
P1 44 – VCF EG3 Intensity
0-15 – 0= EG3 influence off, 1=minimum – 15=maximum.
This parameter determines the amount of influence envelope generator 3 (EG3) will have over the VCF cut off.
P1 45 – EG3 Trigger
0-1 –
0= single trigger
1=multi triggering
This parameter determines if the envelope generator 3 (EG3) will be re-triggered by multiple notes (when set to 1) or if it
will only trigger once for the first note held down (when set to 0).
P1 46 – MK2 Bass Equalization
0-11 – 0 – 6 = lower bass
7 = neutral bass position
8 – 12 = higher bass
When the Poly-800 device global parameter (34) is set to 2 then these parameters become active. If global parameter 34 is
set to 0 or 1 corresponding with Poly-800 MK1 or EX-800 then parameters 46 and 47 are inactive and will not be available
for editing.
P1 47 – MK2 Treble Equalization
0-11 – 0 – 6 = lower treble
7 = neutral treble position
8 – 12 = higher treble
When the Poly-800 device global parameter (34) is set to 2 then these parameters become active. If global parameter 34 is
set to 0 or 1 corresponding with Poly-800 MK1 or EX-800 then parameters 46 and 47 are inactive and will not be available
for editing.
P1 48 – MK1 and EX-800 Chorus Effect
0-1 –
0 = chorus off
1 = chorus on
When the Poly-800 device global parameter (34) is set to 0 (MK1) or 1 (EX-800) then these parameters become active. If
global parameter 34 is set to 2 corresponding with a Poly-800 MK2 then parameter 48 will be inactive and will not be
available for editing.