background image

Overvoltage, under voltage, overcurrect, phase short circuit protection

15 channels subdivision and automatic idle-current reduction

8 channels output phase current setting

Offline command input terminal

Motor torque is related to speed, but not related to step/revolution

High start speed

High holding torque under high speed

Electrical specification:

Input voltage

18-50VDC

Input current

4A

Output current

1.0A

4.2A

Consumption

Consumption

80W

Internal Insurance

6A

Temperature

Working Temperature -10

45

Stocking temperature -40

70

Humidity

No condensation, no water droplets

gas

Prohibition of combustible gases and conductive

dust

weight

300GS

1. Pins assignments and description:

1) Connector Pins Configurations

Pin Function

Details

PUL +,PUL- Pulse signal, PUL+ is the positive end of pulses input pin

PUL- is the negative end of pulse input pin

DIR+,DIR-

DIR signal: DIR+ is the positive end of direction input pin

DIR- is the negative end of direction input pin

ENBL+

Enable signal: ENBL+ is the positive end of direction input pin. This signal is used for

enabling/disabling the driver. High level for enabling the driver and low level for disabling the

Содержание DQ542MA

Страница 1: ...of servo control which enables the motor run smoothly almost without noise and vibration Holding torque when DQ542MA run under high speed is also significantly higher than the other two phase driver...

Страница 2: ...ature Working Temperature 10 45 Stocking temperature 40 70 Humidity No condensation no water droplets gas Prohibition of combustible gases and conductive dust weight 300GS 1 Pins assignments and descr...

Страница 3: ...nd low electrical level When the high electrical level is active all control negative signals will be connected together to GND When low electrical level is active all control positive signals will be...

Страница 4: ...lution is set by SW 5 6 7 8 of the DIP switch as shown in the following table SW5 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF SW6 ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF SW7 ON O...

Страница 5: ...p pulse after 500 ms the driver output current automatically reduced to 70 of rated output current which is used to prevent motor heat 4 Power connections 1 V GND Power Supply V Power supply 16 50 VDC...

Страница 6: ...otor with phase short circuit overvoltage and under voltage protection 2 Troubles Alarm indicator Causes Measures LED off turn Wrong connection for power Check wiring of power Low voltages for power E...

Страница 7: ...signal Change direction setting Motor s holding torque is too small Too small relative to current setting Correct rated current setting Acceleration is too fast Reduce the acceleration Motor stalls R...

Страница 8: ......

Отзывы: