background image

SW4 is used for this purpose. OFF meaning that the standstill current is set to be half of the

selected dynamic current and ON meaning that standstill is set to be the same as the

selected dynamic current.

3) Output current setting:

The first three bits (SW 1, 2, 3) of the DIP switch are used to set the dynamic current. Select a

setting

Closest to your motor’s required current

Output current (A)

SW1

SW2

SW3

PEAK

RMS

ON

ON

ON

1.00

0.71

OFF

ON

ON

1.46

1.04

ON

OFF

ON

1.91

1.36

OFF

OFF

ON

2.37

1.69

ON

ON

OFF

2.84

2.03

OFF

ON

OFF

3.31

2.36

ON

OFF

OFF

3.76

2.69

OFF

OFF

OFF

4.20

3.00

4) Semi-flow function:

Semi-flow function is that there is not step pulse after 500 ms, the driver output current

automatically reduced to 70% of rated output current, which is used to prevent motor heat.

4. Power connections

(1)+V

GND

Power Supply.

+V: Power supply, 16~50 VDC, Including voltage fluctuation and EMF voltage. The max

current is 5A.

(2) A+ A- B+ B-

Connecting 2 phase stepper motors.

The driver & 2-phase hybrid stepping motor use four-wire connection, the motor can be

connected in parallel & series bipolar. As for bipolar connection, it is higher performance with

high-speed, but the current of driver is larger (it is 1.73 times more than the motor’s winding

current).

Connecting in series, the driver’s current is equal to the motor winding one.

5. Fixing

There should be 20mm of space, it can’t be placed next to other heating devices, to avoid

dust, oil mist, corrosive gas, humidity and strong vibration places.

(Unit=mm)

Содержание DQ542MA

Страница 1: ...of servo control which enables the motor run smoothly almost without noise and vibration Holding torque when DQ542MA run under high speed is also significantly higher than the other two phase driver...

Страница 2: ...ature Working Temperature 10 45 Stocking temperature 40 70 Humidity No condensation no water droplets gas Prohibition of combustible gases and conductive dust weight 300GS 1 Pins assignments and descr...

Страница 3: ...nd low electrical level When the high electrical level is active all control negative signals will be connected together to GND When low electrical level is active all control positive signals will be...

Страница 4: ...lution is set by SW 5 6 7 8 of the DIP switch as shown in the following table SW5 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF SW6 ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF SW7 ON O...

Страница 5: ...p pulse after 500 ms the driver output current automatically reduced to 70 of rated output current which is used to prevent motor heat 4 Power connections 1 V GND Power Supply V Power supply 16 50 VDC...

Страница 6: ...otor with phase short circuit overvoltage and under voltage protection 2 Troubles Alarm indicator Causes Measures LED off turn Wrong connection for power Check wiring of power Low voltages for power E...

Страница 7: ...signal Change direction setting Motor s holding torque is too small Too small relative to current setting Correct rated current setting Acceleration is too fast Reduce the acceleration Motor stalls R...

Страница 8: ......

Отзывы: