Instruction Handbook KL
Chapter 9
BA KL V11 en
10/2014
page 9-10
9.4.2
KL 30
– KL 100
Dismounting:
1.
Remove stator. (
Chapter 9.2)
Suction pumps
2.
Undo and remove nuts 1308 between suction housing 1012 and bearing chair1511.
At hopper pumps:
3.
Undo and remove screws 1398 of the fastening of the bearing chair and nuts 1393 on the
bearing chair flange. Pull out bearing chair 1511 as far as possible than undo and remove nuts
1391 of the bearing chair flange.
4.
Pull bearing chair 1511 with joint and rotor out of housing / immersion pipe.
5.
Undo and remove both screws 1957 of a side of the joint with a screwdriver / Allen key.
6.
Remove washers 1961 and O-rings 1958. (Washers 1961 do not apply to types KL30S,
KL50S and KL80S)
7.
Push out old bolt 1959. and replace with a new one after changing the rotor.
Mounting:
1.
Replace the rotor. Insert new O-rings 1958 (put on washers), coat the screws with protective
glue (e.g. Loctite 270, as used in the factory), screw in and tighten.
2.
Renew by every replacement of rotor or drive shaft the O-ring 1962.
3.
Refit all other parts by following the above instructions in reverse order.
Fig. 9-9