Instruction Handbook KL
Chapter 4
BA KL V11 en
10/2014
page 4-1
Connection in the terminal box:
For detailed information on the attachment of the terminal links, see appendix SEW Chapter 5 on
page 61 (de, en). The operating instructions of the drive is available as a PDF-file on CD-ROM. The
CD-ROM is part of the documentation.
4.9
Drive elements
Drive elements must have protection against contact.
4.9.1
Drive shaft
The contact protection of the drive shaft consist two guards in the control holes on the bearing
bracket. These protecting covers can be removed only with a tool.
4.9.2 Coupling elements
Wangen eccentric screw pump with a bare shaft (cylindrical shaft with key) has to connect about an
elastic coupling.
Possible damage
Do not mount the coupling with hammer blows.
Only mount the coupling elements with a mounting device. Use the centre bore at the
thread on the shaft for the positioning.
Line frequency
At field weakening range
Winding voltage
50 Hz
60Hz
50Hz
87Hz
60Hz
104Hz
230/400V
Y
Y
Y
Δ
Y
Δ
400/690V
Δ
Δ
Δ
-
Δ
-
220-230/380-400V
Y
-
Y
Δ
-
-
254-266/400-460V
-
Y
-
-
Y
Δ
380-400/660-290V
Y
-
Y
-
-
-
440-460V
-
Δ
-
-
Δ
-
Warning!
Drive elements move quickly during operation.
Risk of trapping and crushing.
Possible dangerous situation: Severe or fatal injuries
ATTENTION