6�6 Reset to default settings
A reset to the factory settings of the Microwall can be perfor-
med using the recessed mounted service button on the front
panel.
Service button
Press the service button with a suitable pointed object (e.g.
paper clip) and keep it pressed for at least 20s. After 3.5 the
error LED starts flashing slowly and after approx. 10s it starts
flashing fast. After a total of approx. 20s, the device is reset
to the factory settings. If the service button is released while
the service LED is flashing quickly within a time window of
10-20s, the factory default reset is aborted and the Microwall
continues with standard operation according to the current
configuration.
The reset is completed as soon as the system LED is perma-
nently lit again. The Microwall must now be put into operation
again. For more information, please refer to the chapter
Start-
up
.