72
W&T
Appendix
A1.3 Configuration of the System Name
Menu:
2. SETUP System -> 4. System Name -> Type System Name
The freely configurable system name consisting of max. 31
characters is used to identify the LAN-Modem. This name is
displayed as an opening message in the client for all Telnet
sessions.
The factory default setting for the system name is
LanModem-
<wut1>
, whereby the LAN-Modem replaces the keyword
<wut1>
within communication with the last three places of the device-
specific Ethernet address. For example the factory set system
name of a LAN-Modem with Ethernet address 00:c0:3d:01:02:03
is
LanModem-010203
. When using DHCP protocol the system
name is also used for identification with respect to the DHCP
server.
A1.4 Configuration of the System Password
Menu:
2. SETUP System -> 3. System Password -> Type new password
The system password, which consists of any 31 (max.)
characters, protects against any subsequent configuration and
control access to the LAN-Modem.
·
1111: Telnet configuration menu
·
8888: Reset Com-Server
·
IP assignment with
WuTility
On Telnet port 1111 the system password is prompted as soon
as the connection is opened. For all other associated TCP ports
the password must be null-terminated (=[
password
] + 0x00)
and sent to the LAN-Modem no later than 2s after the TCP
connection has been established.
Содержание 58620
Страница 1: ...Release 2 0 January 2010 Model 58620 Firmware 2 10 or higher Manual LAN Modem W T...
Страница 6: ...6 W T...
Страница 10: ...10 W T Quickstart...
Страница 22: ...22 W T Assigning the IP address...
Страница 34: ...34 W T LAN Modem operation settings...
Страница 89: ...89 W T Appendix Subject to error and alteration...