Startup
5. Startup
Once the Web-IO has been properly installed and wired,
the power can be turned on. All three status LEDs should
come on briefly. After approx. 5 seconds only the Power LED
should remain on. The Status LED may flash. If a valid signal
is detected on one of the inputs, the corresponding LED will
come on.
When a network is connected the green LED in the network
socket will indicate an existing link. The orange LED provides
information about the network speed.
On = 100MBit/s
Off = 10MBit/s
Assigning the IP address
IBy default IP address 0.0.0.0 and DHCP is activated on the
Web-IO.
Networks with DHCP
If a DHCP server is active in the network in which the Web-IO
is connected, an IP address should be automatically assigned
to the Web-IO. To be able to specifically access the Web-IO,
you should configure a reservation in the DHCP server so that
the Web-IO is always accessible under the same address. The
required Ethernet address can be found on the white sticker on
the device.
5763x
[Model]
EN=00c03d003fa0
OK xxxxxx
Ethernet address
(If in doubt ask your network administrator)