149
W&T
Subject to errors and modifications
7.4 Emergency access
The device can be reset to its factory default settings in the
following manner:
1. Open the housing
The DIN rail mount housing is opened by plugging in the 6-pin
connector. After tightening both the fastening screws the board can
be removed from the housing by pulling on the connector.
2. Insert module jumper
A jumper is located on the offset module. Insert this jumper and
ensure that a network cable with a link to a hub or switch is
connected to the device.
3. Reset
Turn on the device with the jumper in. The device flashes the
„System-Error“ and „On-Error http://“ several times. After
approximately 30seconds the device is restored to its factory
default settings.
!
Resetting is done only using the jumper on the module
board. Please always leave the two other jumpers on the
motherboard out!