7.3.3 LED indicators
■
Power-LED:
Indicates that power is present. If the LED is not
on, please check for a proper supply voltage connection.
■
Status-LED:
Flashes whenever there is network activity with
the Web-IO Analog. Periodic flashing indicates a ready state.
■
Error-LED:
The Error LED uses various flash codes to
indicate error states on the device or network port.
1x flashing of the Error-LED
= Check network connection.
The Web-IO Analog is not receiving a link pulse from a hub
or switch. Check the cable or the hub/switch.
2x or 3x flashing of the Error-LED
= Disconnect power to
perform a reset. If this does not clear the error, reset the device
to its factory default values. Since this resets all the network
settings, you should first write down your current network
settings.
Config -> Session Control -> LogOut -> Restore Defaults
After a reset the device is restored to its factory default
settings. Reenter your desired network settings.
Power-LED +Status-LED +Error-LED on = Self-test error
The self-test performed by the Web-IO each time it is started or
reset may - for example due to an incomplete firmware update -
not be correctly executed. In this state the device is no longer
functional. Please return the device.
Содержание 57661
Страница 1: ...W T Manual Web IO Analog In Out PoE Type 10 100BaseT 12 24V Model 57661 57662 Release 1 63 Jun 2010...
Страница 11: ...11 W T Subject to errors and modifications Jumper directly on the device Jumper at the remote end...
Страница 31: ...31 W T Subject to errors and modifications Configuring the voltage input and output Model 57662...
Страница 64: ...64 W T Then click on the Apply button to send the settings to the Web IO...
Страница 102: ...102 W T...
Страница 142: ...142 W T The Web IO displays this page in the Web browser as follows...