101
W&T
Subject to errors and modifications
device to use. If the e-mail port is not the same as the standard
port 25, append the actual port to the address using a colon:
mail.provider.de:476
Authentication:
If authentication is required on the mail server,
enter here the corresponding procedure for user identification:
SMTP authentication off:
No authentication
ESMTP:
A user name and password are required in order to log in
on the mail server.
SMTP after POP3:
For an SMTP access it is necessary first to
access through POP3, so that the user can be identified. For this
setting you also enter an associated POP3 server.
Enable:
Be sure that the „Mail enable“ checkbox is checked for e-
mail sending
3.16.2 Alarm X