4.0 SETTING THE OPERATING PANEL & USE
QE SEPCOM SIP BED EASY
List of possible alarms, description and type:
Alarm
Description
Type
MINIMUM
CURRENT
Minimum setpoint value has been reached
Shut-down
PRESSURE
FAULT
Shut-down
NO AIR
SUPPLY
Air leak: Check air line between separator, cylinders, control panel and pressure
switch
Shut-down
LOW LEVEL
OF THE TANK
Low level in feeding tank upstream the separator
Warning
THERMAL
PROTECTION
Maximum current value reached
Shut-down
AUXILIARIES
DISABLED
Users not connected
Shut-down
MAXIMUM
CURRENT
Maximum setpoint value has been reached
Warning
IMP ABSORP-
TION. NOT
REACHED
The separator electric motor cannot reach the absorption setpoint
Shut-down
AGITATOR
MAINTENANCE
Maintenance required on the agitator
Warning
PUMP
MAINTENANCE
Maintenance required on the feeding pump
Warning
SEPCOM
MAINTENANCE
Maintenance required on the separator: check the oil level in the gear reduction
unit
Warning
SCREEN
MAINTENANCE
Maintenance required on the screen: reverse the inlet/outlet position of the
screen to extend its life or replace it if you have already reversed the position.
Warning
SCREW
MAINTENANCE
Maintenance required on the screw: check for wear on the outlet side
Warning
GREASE NIPPLE
MAINTENANCE
Maintenance required on the grease nipple: replace the cartridge
Warning
Depending on the type of alarm, the reaction of the separation system changes:
- warning alarm: video signalling, active alarm and red indicator light on;
- shut-down alarm: video signalling, active alarm, red indicator light on and system shut-down.
When the alarm has tripped, the system stops at the end of the cycle and the cycle does not start either with
the levels giving it an external call or with the start button.