How to store the MSLD MOB ID

The W440 AIS Sart Sniffer lets you store up to 8 AIS SART codes, so that 

the alarm is activated only for codes stored (unless this feature is disabled,
see the dip switch setting).

 

To store a code (or overwrite), proceed as follows:

1.

Move the knob selector in position C and keep it pressed for 5 

seconds.

2.

The lamp switch will begin to flash at a rate of 1 flash per second; 

each flash indicates the memory position currently in use (1 flash 

= position 1, position 2 = 2 flashes, etc.).

3.

To change the memory location simply release the switch to its 

central location for a couple of seconds and repeat the procedure 

from step 1. The new location will be the next to the previous one.

4.

Release the switch back to position B. The luminous body of the 

switch will continue to flash indicating the selected memory 

location.

5.

Turn on a AIS SART device nearby, make sure the device is 

activated in MOB TEST mode and IT makes a test transmission 

(check the instructions in the manual of the manufacturer of the 

MOB  equipment).

6.

After a successful transmission and subsequent reception of AIS 

message, the W440 will indicate acceptance of the new ID code 

with light on (no flashing) and audible beep by a duration of 2 

seconds.

7.

The W440 has stored the new code in the AIS position required 

and your unit is back to the operating mode. 

11

EN   

Содержание W440

Страница 1: ...W440 AIS Sart Sniffer Ed 1 4 0 EN 5 2015 Instruction manual...

Страница 2: ...Doc W440_1_4_0_EN...

Страница 3: ...3 Picture 1 Frontal view 1 4 3 2...

Страница 4: ...4 Picture 2 Schematic diagram...

Страница 5: ...centers of electrical and electronic rubbish indicated by local authorities The proper separate waste of end life devices for recycling treatment environmental compatible disposal helps avoiding poss...

Страница 6: ...and thank you for purchasing the W440 AIS SART Sniffer one of the most high tech reliable devices available on the market As the owner of this radio device you are advised to Read this manual Adopt a...

Страница 7: ...ace NMEA 0183 galvanic isolation Impedance 800 Ohms Speed 38400 baud AIS Sentence AIVDM AIS ID in memory Up to 8 Activation Rotary knob switch Optional Auxiliary switch contact or message 1A 250 VAC P...

Страница 8: ...er wire with almost 0 75 mm2 size We suggest to use the schematic diagram on page 4 In detail as for the wire connector marked as 1 upper part please see the following connections Pin Connection type...

Страница 9: ...xplained in the chapter Using the W440 and its programming For connection to the data output of your receiver use the NMEA two terminals pin 6 and 7 of the lower connector This port is capable of acce...

Страница 10: ...440 unit is also equipped with two DIP switches located to the left of the lower connector 4 Their function is the following DIP Switch Open Close On position 1 The alarm is activated only if the AIS...

Страница 11: ...l location for a couple of seconds and repeat the procedure from step 1 The new location will be the next to the previous one 4 Release the switch back to position B The luminous body of the switch wi...

Страница 12: ...MOB alert message If an AIS MOB or SART unit able to send a message like MOB ACTIVE or SART ACTIVE is activated in range of your radio equipment the W440 unit will recognize the NMEA sentence and beha...

Страница 13: ...larm please switch off the W440 unit Turning off the alarm and reset To turn off your device W440 or reset an alarm received simply move the switch in position A Please note that The programmable ID c...

Страница 14: ...lower connector see figure point 4 The software is free and it can be downloaded from the company website www wamblee it under the heading W440 It allows you to set any ID AIS code without having to...

Страница 15: ...Note 15 EN...

Страница 16: ...Wamblee s r l Via Vittori 19 48018 FAENZA RA ITALY Tel 39 0546 623891 Fax 39 0546 623891 email info wamblee it Made in Italy 16...

Отзывы: