DPC130X
ATEX DPC130X is an open/closed circuit sectional valve:
• its operating principles are based on the precompensated Load Sensing technology;
• which has been conceived to be adequate to work in potential explosive areas according to the requirements of ATEX Directive
2014/34/UE.
_________________________________________________________________________________________
Valve description
Operating principle of Pre-Compensated Load Sensing technology
The main feature of this principle is that the flow rate to the user is proportional to the spool position under any operating
condition, regardless of the resistance encountered by the user (pressure) and the number of activated levers (exceeding the
pump’s total flow rate, a condition hereinafter defined as saturation, is the only limitation).
V2
V1
LS
T
P
B1 A1
L
B2 A2
LSAB
LSAB
V2
V1
LS
T
P
B1 A1
L
B2 A2
LSAB
LSAB
Closed center circuit example
Open center circuit example