background image

 

Revision 12 

 

 

12 

Product Manual Solid Surface WC Pans 

5.5. 

Technical Specifications 

 

Weight 

50 - 70Kg (Dependent on CWC model). 

Dimensions 

Refer to CWC model drawing supplied separate to these 
instructions. 

Water Supply 

Refer to the applicable product manual for the WC flush device. 

Soil pipe connection 

105/108mm external diameter male spigot. 

Flush pipe inlet 

55mm internal 

diameter female for 1.5” size pipe & pipe seal. (as 

supplied with flushing device). 

Flushing device flow 
requirements 

Cistern flush: 1.85 

– 2 Litres per second. 

Direct flush: 1.5 Litres per second (nominally). 
 
Refer to flushing device product information for full details. 
 

Optional Control Unit Specifications 

Power supply  

230V AC 50/60Hz 2 Amp single phase 

USA / CANADA: 

120V AC 2Amp, 60Hz for models WDCA100 and WDCA200. 

Power rating 

Maximum power rating 60 W 

Weight 

1.0 Kg 

Dimensions 

200mm (W) x 150mm (H) x 80mm (D) 

Enclosure IP Rating 

IP53 

Regulatory 
compliance 

Complies with RoHS, LVD 2006/95/EC and EMC 2004/108/EC 
directives.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CWC-150 series

Страница 1: ...Product Manual Solid Surface WC Pans CWC 80 CWC 280 series CWC 150 CWC 250 series CWC 170 CWC 270 series CWC 155 CWC 255 series ...

Страница 2: ...Revision 12 2 Product Manual Solid Surface WC Pans AS 1172 Certificate No 23109 ...

Страница 3: ...lists 5 2 5 Menu items 5 3 Glossary 6 4 Overview 7 5 Installation and Commissioning 8 5 1 Package Contents 8 5 2 Site Preparation 8 5 2 1 Mounting Guidelines 8 5 3 Preparing fitting the Water Closet 9 5 4 Commissioning for use 11 5 5 Technical Specifications 12 6 User and Maintenance Instructions 13 6 1 Operation 13 6 2 Maintenance 13 7 Related Documentation 14 ...

Страница 4: ...on at any time without prior notice This manual is specific to the product that it has been supplied with at the date of supply Without prejudice to any warranties in Wallgate Limited s terms and conditions of sale any warranty will be invalidated if the equipment is installed or serviced by unqualified personnel No part of this publication and the information contained may be reproduced transmitt...

Страница 5: ...stall and commission the CWC water closet Failure to heed these warnings can have serious consequences WARNING This is a warning 2 2 Note A note with black text on a yellow background is used to draw your attention to important and useful information NOTE This is a note 2 3 Numbered procedures Steps in procedures are numbered starting from 1 1 This is step 1 2 This is step 2 etc 2 4 Bullet lists 2...

Страница 6: ...a dedicated water supply that has the required pressure flow performance to suit the application These devices are not suitable for domestic some commercial installations Piezo electric Touch button A piezo electric touch button converts the force applied to the face of the pushbutton into an electrical signal Piezoelectric pushbuttons are used on related optional flush devices for the CWC water c...

Страница 7: ...h M6 fixing points for hinged seat option with fixed extension shroud to accommodate soil connectors exiting through floor CWC 150 250 Back to wall WC pan CWC 150 AST 250 AST Back to wall WC pan with fixed solid surface anti ligature seat CWC 151 251 Back to wall WC pan 455mm height for disabled users seat fixings optional CWC 151 EXT 251 EXT Back to wall WC pan 455mm height for use with hinged se...

Страница 8: ...llgate sales desk for more information 5 2 Site Preparation 5 2 1 Mounting Guidelines The CWC is a back to wall type pan for installations with a concealed but accessible flushing device The CWC is suitable for various types of flushing device that Wallgate can provide have been tested to ensure compliance compatibility with the WC pans The flushing device is to provide a max full flush volume of ...

Страница 9: ...ater Closets weigh more than 25Kg so a two man lift is recommended Always use safe lifting procedures when lifting heavy loads For large installations of several water closets an optional lifting hook is available from Wallgate WARNING To maintain the anti ligature anti vandal properties of this product it must be installed in line with the following points 1 Ensure product fixings are correctly f...

Страница 10: ...flushing device into the top hole on the back of the WC pan 7 Locate the CWC outlet spigot into the soil pipe connector and position the WC into place with the extension if applicable 8 Assemble the wall bracket nuts and washers onto the M10 wall studs Check that the back of the wc pan has fitted to the wall without any gaps due to an uneven wall finish prior to tightening each fixing to a torque ...

Страница 11: ...that provides for seat fixing points i e CWC 80 CWC 81 CWC 151 SF Fitting the seat must be done in accordance with the instructions provided with the WC seat 5 4 Commissioning for use To commission the CWC Water Closet 1 Turn ON the water supply check all around for leaks on the flushing device the pan water inlet outlet connectors 2 Depending upon which type of flushing device has been fitted you...

Страница 12: ... 1 5 size pipe pipe seal as supplied with flushing device Flushing device flow requirements Cistern flush 1 85 2 Litres per second Direct flush 1 5 Litres per second nominally Refer to flushing device product information for full details Optional Control Unit Specifications Power supply 230V AC 50 60Hz 2 Amp single phase USA CANADA 120V AC 2Amp 60Hz for models WDCA100 and WDCA200 Power rating Maxi...

Страница 13: ...s for full details regarding operation set up 6 2 Maintenance The CWC is manufactured from a cast solid surface composite that is very durable A planned on going care maintenance routine will ensure that the product will last for many years Refer to the Care Maintenance Instructions Leaflet available from Wallgate www wallgate com Further advice on this other Wallgate products may be obtained by c...

Страница 14: ...re information on this flushing device refer to the CIST19 PNEU product manual Drawings of CWC pan models typical installation layout drawings CWC 80 CWC 80 EXT CWC 80ST CWC 80ST EXT CWC 81 CWC 81 EXT CWC 81ST CWC 81ST EXT CWC 280 CWC 280 EXT CWC 280ST CWC 280ST EXT CWC 281 CWC 281 EXT CWC 281ST CWC 281ST EXT CWC 150 CWC 150 SF CWC 150 AST CWC 151 CWC 151 SF CWC 151 AST CWC 155 CWC 155 SF CWC 155 ...

Страница 15: ...Revision 12 15 Product Manual Solid Surface WC Pans PAGE INTENTIONALLY LEFT BLANK ...

Страница 16: ...Revision 12 2 Wallgate Ltd Crow Lane Wilton Salisbury Wiltshire SP2 0HB England tel 44 0 1722 744594 fax 44 0 1722 742096 email service wallgate com web www wallgate com ...

Отзывы: