G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 3 

 

1.  GENERAL VIEW & CONNECTIONS 

 

Figure 3: General view 

 

 

 

NOTE: - The Multisan-Pro pump unit MUST be installed in dry weatherproof, non-floodable location with easy access 

for operation, maintenance and repairs. Any damage to pump unit or any other item due to non-compliance of this 

clause or any other instructions in this manual is not covered under warranty. 

 

1a. 

Cover 

for dry mounted pump, motor and controls. Remove the fastening safety screw holding cover to tank and then pull and 

lift to remove. 

 
1b. 

Collection Tank 

- Fittings supplied may be shipped inside. Please check carefully in the tank and remove all fittings / parts. 

Any fitting / part left in tank will damage pump. Do not subject the tank to impacts, scratches, scouring or any drilling that may 
weaken it. 

 
2. 

Inspection lid 

- Screw in with o-ring seal; turn anti-clockwise to open. Install upright with the inspection lid on top. 

 
3. 

Pan connection

 - Only one WC pan connection is provided and is allowed per installation. 

The standard vitreous P type pan discharge to be connected directly to the tank at pan connection provided on tank with 
suitable rubber gasket. Do not damage the raised lip and groove. Wet the gasket with soapy water before fitting to make fitting 
easier. If bends are unavoidable, keep to a minimum and use only swept inspection bends. 

 
4. 

Pump delivery - 

32 mm BSPF with gasket. 

Use PVC pressure pipe

. Recommend to install a Mac union connector close to 

the pump, then the 32 mm solvent weld end swing check valve (9) and then 32mm solvent weld end isolating ball valve (10) 
to allow for future maintenance. Securely strap and isolate the pipe from the building structure to prevent vibration or noise 
transmission during operation. Any horizontal section of the delivery pipework should always have a continuous rise towards 
the soil or waste pipe connection. It should never be level or have a fall. 

 
5. 

Tank vent connection

 - 40 mm moulded Vent connection with carbon is provided on the tank for localised venting. If outside 

vent is required as per local rules & regulations, remove the carbon vent, floating ball & gasket inside the moulded vent 
connection. Insert the 40mm PVC fitting provided in the rubber sleeve. Use 40 mm pipe to run the vent to a termination point 
in accordance with the Building and Plumbing Code. 

Do not use an air admittance valve

, e.g. a 

"Hunter Valve".

   

 
6. 

Shower / Bath connection

 - One special 40mm connection with one way valve is supplied as fitting. This need to be used 

for connecting a shower or a bath to pump unit. 

Refer photos below for details

. This should not be shared with any other 

connecting fixtures or appliances. If both are connected, each must have its own valve. The extra connection can be purchased 
from Wallace Pumps if required. This connection is 100 mm centre height from the base floor level. The inlet pipe must be 
properly braced to prevent the water pressure from dislocating the push-fit connection. The shower tray or /and bath outlet 
must be minimum 180mm from base floor level height. Distance between the pump and the shower or/and bath will decide 
the height of the shower or /and bath outlet to achieve pipe fall from shower or bath to pump as per building & plumbing code 
/ regulations. 

 
 
 
 
 
 
 

1a:- Pump Cover 

1b:- Collection Tank

2:- Inspection 
lid

3:- Pan connection 

4:- Pump delivery 

5:- Tank vent 

ti

 

6:- Shower / Bath connection

7:- Additional Inlet 

ti

WARNING – Pump 
Cover is not water 
tight. Water dripping 
on to Pump Cover 
may cause pump 
failure and hazard. 

Содержание MULTISAN PRO

Страница 1: ...ge pump For this product to meet its expected lifetime please ensure it is installed by a qualified technician and follow the maintenance schedule as detailed in section 13 2 Please keep a record of b...

Страница 2: ...mp and motor unit Toilet pan connection Gas and watertight collection tank Pump cover Manual Run Reset Button Tank Vent provided with Carbon Use this port in case need to vent outside via vent pipe Do...

Страница 3: ...olate the pipe from the building structure to prevent vibration or noise transmission during operation Any horizontal section of the delivery pipework should always have a continuous rise towards the...

Страница 4: ...nic products such as condoms sanitary pads wet wipes tampons nappies sand stones tar cement coarse paper non water soluble paper towels cardboard plastic bags fat oil etc in the toilet to be affixed t...

Страница 5: ...al limitations or because there was no unit available with adequate performance The MULTISAN PRO has been developed to overcome these problems including Below sewer line installations Where gravity fa...

Страница 6: ...able check your installation requirements against the dimensions and hydraulic capabilities of the unit This graph is based on a flow of 35 litres min If flows exceed 35 L min please contact Wallace P...

Страница 7: ...pigot connecting to pump other end socket to connect waste pipe from WHB Sink or any other domestic appliance and to connect 40mm DWV pipe as vent connection if required as per local rules and regulat...

Страница 8: ...r bigger cable Check with Wallace Earth wire to be connected to Earth terminal E as shown Volts Free Contacts in the circuit board which activates in case of Alarm Connect Volts Free Terminal No 1 com...

Страница 9: ...transmission 3 Install only the supplied full flow non clog swing check within one metre of the pump in a vertical position below and close to the supplied isolating ball valve 5 All pumped appliance...

Страница 10: ...evel difference between WC pan and pump unit should NOT BE MORE THAN 900mm Suitable access must be provided for operation maintenance and repairs of the unit at all times An adequate overflow outlet m...

Страница 11: ...between services should be 6 months for heavy usage unit and 1 year for light to medium usage unit c All Alarm activation occurred to be noted as to when date time and how and who rectified it and wha...

Страница 12: ...quid Level switch operated by water level remains in the ON position because a pipework is blocked or b pump is blocked or c tank is blocked or d delivery hose is kinked e pressure switch is water log...

Страница 13: ...t intervals without any liquid discharged into the collection tank Water is leaking back flowing into the unit from the delivery pipe triggering the motor to re start Non return valve does not close p...

Страница 14: ...nk chamber under the cover Power is off Overload trip Inflows exceeding pump capacity Blockage in the pipework Shower pipe also has other pipes connected to it Pump malfunctioning Overflow pipe if app...

Страница 15: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 15 16 Spare Parts drawing list pump unit...

Страница 16: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 16 Complete lifting unit...

Страница 17: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 17 Circuit board...

Страница 18: ...hose MICROBOY 117604 1 330 2 Hose clip 20 32 117033 1 340 2 O ring 34 52x3 53 117034 1 350 4 Rubber foot 117035 1 360 2 Countersunk 3 5x9 5 117605 1 370 1 Non return valve valve 117056 1 410 1 Lense h...

Страница 19: ...m flange MICROBOY E2 117002 1 2 280 1 O ring 120x2 5 117007 2 290 4 Lens head screw 4 2x19 270024 2 300 1 O ring 72x3 5 117700 2 310 1 Cutting plate 117198 2 320 3 Countersunk M4x8 117199 2 330 1 Hose...

Отзывы: