G:\INSTRUCT\MULTISAN PRO\Multisan Pro Instructions 251119.docx Page 11 

 

 

These remote installations must have the pan vented as normally required for a gravity flow installation, this vent is not shown 

on these diagrams. 

 
 

 

13.  CARE AND SERVICING OF YOUR UNIT

 

 

13.1 Protect the Multisan-Pro unit from weather or flooding or frost. Any damage to unit due to no protection is not 
covered under warranty. 

 

13.2 Regular Servicing 

 
Ensure isolation and disconnection of the power supply to the pump before and whilst carrying out any servicing work on the unit. 
Also ensure no liquid will flow into it during servicing. 

 

For this product to meet its expected lifetime please ensure it is installed by a qualified technician and 
following maintenance schedule must be followed. A record of by whom and when the maintenance was 
completed to be kept and that need to be provided to us when asked for. 

 

a)  The MULTISAN-PRO pump must be serviced at regular intervals by Wallace Pump’s authorised Service Agent or a 

qualified technician who understands the product operation and maintenance. 

 

b)  The maximum interval between services should be 6 months (for heavy usage unit) and 1 year (for light to medium usage 

unit) 

 

c)  All Alarm activation occurred to be noted as to when (date & time) and how and who rectified it and what was the reason. 

 

 
Following (minimum but not limited to) servicing / maintenance work to be done by technician during every service call and records 
must be kept with signature of the servicing person, date of servicing and actual work done and observations. 

The interior of the collection tank and dip tube should be clean from any sludge or muck building. 

Check and ensure pump starts and stops at normal levels and pump out as per site conditions and pump curve. 

Check for any abnormal noise or operation  

Record if any part was changed / replaced and why  

 
Ensure isolation and disconnection of the power supply to the pump before and whilst carrying out any servicing work on the unit. 
Also ensure no liquid will flow into it during servicing. 
 

13.3 Modifications or Repairs:

 Wallace Pumps does not warrant for any damage to the unit or any other property caused by 

any un-authorised modifications/repairs in contravention with the Company's instructions or by use of materials or fittings not 
supplied by Wallace Pumps. Where a claim arises, we suggest you contact the installer for rectification. 
 
 
 
 
 
 
 
 
 
 

Содержание MULTISAN PRO

Страница 1: ...ge pump For this product to meet its expected lifetime please ensure it is installed by a qualified technician and follow the maintenance schedule as detailed in section 13 2 Please keep a record of b...

Страница 2: ...mp and motor unit Toilet pan connection Gas and watertight collection tank Pump cover Manual Run Reset Button Tank Vent provided with Carbon Use this port in case need to vent outside via vent pipe Do...

Страница 3: ...olate the pipe from the building structure to prevent vibration or noise transmission during operation Any horizontal section of the delivery pipework should always have a continuous rise towards the...

Страница 4: ...nic products such as condoms sanitary pads wet wipes tampons nappies sand stones tar cement coarse paper non water soluble paper towels cardboard plastic bags fat oil etc in the toilet to be affixed t...

Страница 5: ...al limitations or because there was no unit available with adequate performance The MULTISAN PRO has been developed to overcome these problems including Below sewer line installations Where gravity fa...

Страница 6: ...able check your installation requirements against the dimensions and hydraulic capabilities of the unit This graph is based on a flow of 35 litres min If flows exceed 35 L min please contact Wallace P...

Страница 7: ...pigot connecting to pump other end socket to connect waste pipe from WHB Sink or any other domestic appliance and to connect 40mm DWV pipe as vent connection if required as per local rules and regulat...

Страница 8: ...r bigger cable Check with Wallace Earth wire to be connected to Earth terminal E as shown Volts Free Contacts in the circuit board which activates in case of Alarm Connect Volts Free Terminal No 1 com...

Страница 9: ...transmission 3 Install only the supplied full flow non clog swing check within one metre of the pump in a vertical position below and close to the supplied isolating ball valve 5 All pumped appliance...

Страница 10: ...evel difference between WC pan and pump unit should NOT BE MORE THAN 900mm Suitable access must be provided for operation maintenance and repairs of the unit at all times An adequate overflow outlet m...

Страница 11: ...between services should be 6 months for heavy usage unit and 1 year for light to medium usage unit c All Alarm activation occurred to be noted as to when date time and how and who rectified it and wha...

Страница 12: ...quid Level switch operated by water level remains in the ON position because a pipework is blocked or b pump is blocked or c tank is blocked or d delivery hose is kinked e pressure switch is water log...

Страница 13: ...t intervals without any liquid discharged into the collection tank Water is leaking back flowing into the unit from the delivery pipe triggering the motor to re start Non return valve does not close p...

Страница 14: ...nk chamber under the cover Power is off Overload trip Inflows exceeding pump capacity Blockage in the pipework Shower pipe also has other pipes connected to it Pump malfunctioning Overflow pipe if app...

Страница 15: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 15 16 Spare Parts drawing list pump unit...

Страница 16: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 16 Complete lifting unit...

Страница 17: ...G INSTRUCT MULTISAN PRO Multisan Pro Instructions 251119 docx Page 17 Circuit board...

Страница 18: ...hose MICROBOY 117604 1 330 2 Hose clip 20 32 117033 1 340 2 O ring 34 52x3 53 117034 1 350 4 Rubber foot 117035 1 360 2 Countersunk 3 5x9 5 117605 1 370 1 Non return valve valve 117056 1 410 1 Lense h...

Страница 19: ...m flange MICROBOY E2 117002 1 2 280 1 O ring 120x2 5 117007 2 290 4 Lens head screw 4 2x19 270024 2 300 1 O ring 72x3 5 117700 2 310 1 Cutting plate 117198 2 320 3 Countersunk M4x8 117199 2 330 1 Hose...

Отзывы: