4
Step 4: Main blade pitch setting
The recommended pitch range is ±10°; the flight limit is ±11°.
CAUTION:
The adjustment of servo travel in a CCPM system must be made using the transmitter
‘SWASHMIX’ function, do not adjust the servo travel individually.
10.5.2
S
WASHPLATE MIXING SET
-
UP FOR
E
LEVATOR AND
A
ILERON SERVO TRAVEL
Step 1: Enter set-up mode for ELEV travel
Follow the steps in section 10.5.1 to enter neutral point set-up, once completed return PIT to the
neutral point and press the “SET” button a second time.
The STATUS LED will turn constant RED and the ELEV LED will flash GREEN. The elevator servo travel
mode is now selected.
Step 2: Swashplate elevator travel setting
Without moving any of the other controls push the elevator control stick of the transmitter to the
highest position, while keeping max ELEV, press the “SET” button to confirm the extent. The receiver
calculates the CCPM mixing ratio and the usable travel of forward and backward.
The STATUS LED remains RED, the ELEV LED turns off and the AILE LED flashes GREEN. Return the
elevator stick on the transmitter to neutral.