![Walker C19i Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/walker/c19i/c19i_operators-manual_869810069.webp)
65
Maintenance Instructions
CHECKING/SERVICING
Blade Balancer
Blade Balanced on Magnetic
Wall-Mounted Balancer
7. Mount the blade with wing tips pointing up into
the housing. For
gear driven decks
reinstall
the blade, washer, lock washer, and nut.
Tight-
en the nut to 60 lb·ft (81 N·m).
For
belt driven
decks
reinstall the spacer (if applicable), blade,
washer, and bolt.
Tighten the bolt to 70 lb·ft
(90 N·m).
NOTE:
When reinstalling blades on
GHS
mod-
els, remember, the
blades
counter-rotate and
the LH and RH blades must not be switched.
Check for proper blade rotation before installing
blades on the deck. Refer to
Blade Rotation
illustrations shown in
Clogging Checklist
in
Operating Instructions
for correct blade rotation.
Drive Belts
Raise the body and inspect the condition of the
four (4) belts
every 25 hours
of operation - engine
PTO drive, jackshaft drive, hydrostatic ground drive,
and GHS blower drive. If the belts show
signs of
cracking or deteriorating,
the belts should be
re-
placed.
Refer to
REPLACING/REPAIRING
the
Drive Belts
in this section.
Mower Deck Gearbox Oil Seals
The mower deck gearbox seals should be inspected
every 25 hours
for evidence of oil leaking;
particu-
larly the lower oil seal on the blade drive gearbox.
This seal is protected by the trash guard on the blade
hub and seal protector plate on the housing, but is
still vulnerable to seal damage due to operating in
an adverse environment. The mower blade must be
removed for inspection of the seal, so it is recom-
mended to
inspect the gearbox seals when blades
are removed for sharpening.
If an oil leak is not-
ed, the seal should be replaced and the gearbox
assembly relubricated. Refer to
LUBRICATION
for
Mower Deck Gearbox Lubrication
in this section.
Spark Plugs
Every 200 hours
of operation, remove the spark
plugs, inspect, clean, and reset the gap (or replace
with
new plugs
). Before removing the spark plugs,
clean the area around the base of the plugs to keep
dirt and debris out of the engine. Clean spark plugs
with a wire brush. DO NOT use an abrasive grit type
cleaner. If the electrodes are burned short or pitted,
replace plugs with Champion‚ type RC12YC (or
equivalent). Check spark plug gap with a wire-type
feeler gauge and set the gap at 0.030 in. (0.76 mm).
Reinstall and tighten to between 18 and 22 lb
·
ft
(24 to 30 N
·
m).
Ignition Wires
Good preventive maintenance calls for complete
re-
placement
of spark plug wires
every two (2) years.
Fuel Lines and Clamps
NOTE:
The fuel injection system is pressurized and
should be serviced by a Walker dealer or authorized
Kohler engine service outlet.
Every year,
inspect the fuel supply line from the
tank to engine for deterioration or damage. Also,
inspect the fuel line
clamps for tightness.
Good
preventive maintenance calls for complete
replace-
ment
of fuel lines and clamps
every two (2) years.
Engine Starter
Yearly or every 500 hours
disassemble and clean
the solenoid shift starter. Refer to the Kohler Service
Manual for this procedure or contact an authorized
Kohler engine dealer to perform this service.
Содержание C19i
Страница 80: ...76 Operator s Notes ...
Страница 81: ...77 Operator s Notes ...
Страница 82: ...78 Operator s Notes ...