800-WMAGNET
16 of 33
5.3 Chuck Control Connections
Adjustments
Number of Release Pulses (1-16) - Set to 8 pulses at factory (See Release section 4.5 page 4-3)
Table 5-1 Terminal TB1
1
(+)
Chuck DC
2
(-)
Chuck DC
Table 5-2 Connector - J4
1,2
Lockout Supply Relay Contacts
3,4,5
Part Released Signal Relay Contacts
6,7,8
Current Sense Relay Contacts
Table 5-3 Connector - J5
1
50K Ohm Variable Potentiometer
2
GND
3
Release Lamp
4
Variable Lamp
5
Full Lamp
6
Residual Lamp
7
LED Common
8
Lockout Option
9
Variable Pushbutton
10
Full Pushbutton
11
Residual Pushbutton
12
Release Pushbutton
13
GND (Pushbutton Common)
14
+5V
15
# of Release Pulses
16
Lamp Common