5.2.2 BLOWER OIL CHANGING AND BREATHER CLEANING
The gears that drive and time the
blower lobes run in an oil bath for
lubrication. Maintaining the correct
level in the reservoirs and changing
every 100 hours will insure proper
lubrication.
When maintaining the blower, follow
this procedure:
1. Clear the area of bystanders,
especially small children.
2. Turn machine off, lock out tag out
master control panel and wait for
all moving parts to stop before
starting maintenance work.
3. Unlatch and remove the belt drive
covers.
4. Checking Oil Level:
a. Remove the level plug in each
reservoir or check the sight
glass.
IMPORTANT
Check the level only when the
oil is cold and the machine is
level.
b. Oil in the reservoir should just fill
the threads of the level plug hole.
c. Add oil if low or allow the reservoir to drain if
overfilled.
IMPORTANT
It is necessary to maintain the recommended oil
level in the reservoir. A low level causes heating
from lack of lubrication and rapid gear and
bearing wear. Too much oil causes heating from
oil churning and can cause seal and breather
leaks.
d. Install and tighten the level plug.
e. Install and secure the belt covers.
-Vent Holes
Vent Holes
Oil Level
/ Sight
\
Glass
Schematic
Front
Rear
Fig. 5.13 BLOWER