108
User’s Manual MicroWave II • MicroWave XT • XTk
179-206 IDATA
see 3.3
Instrument #6 data
207-234 IDATA
see 3.3
Instrument #7 data
235-262 IDATA
see 3.3
Instrument #8 data
263 XSUM
(BB+NN+DATA)&7Fh Checksum
264 EOX
F7h End of SysEx
------------------------------------------------------
******************************************************
2.23 MULP
******************************************************
MULP 20h Multi Parameter Change
Upon reception of a valid Multi Parameter Change dump,
the specified parameter will change its value
immediately according to the given value. In Sound
Mode, all MULP messages will be ignored. The location
is given in one byte with following conventions:
LL
Location
------------------------------------------------
20h
Multi Edit Buffer
01h..07h
Multi Mode Instrument 1..8 buffer
------------------------------------------------
The Parameter index is given in one byte:
PP
Parameter index
------------------------------------------------
00..1Fh Parameters with indices 0 to 31
------------------------------------------------
See 3.2 for a detailed list of Multi parameters and
indices, or 3.3 for a detailed list of Instrument
parameters and indices.
The actual Format is:
Index Label Value Description
------------------------------------------------------
0 EXC F0h
Marks Start of SysEx
1 IDW 3Eh
Waldorf Electronics
GmbH ID
2 IDE 0Eh
Microwave 2 ID
3 DEV
Device ID
4 IDM 21h
here MULP (Sound
Parameter change)
5 LL see above Location
7 PP see above Parameter index
8 XX see 3.2/3.3
New Parameter value
9 EOX F7h
End of Exclusive
------------------------------------------------------
******************************************************
2.31 WAVR
******************************************************
WAVR 02h Wave Request
Upon reception of a valid wave request the MW2 will
dump the selected Wave. The location is given in two
bytes with following conventions:
HH LL
Location
------------------------------------------------
00 00 .. 00 7F
ROM Waves 000..127
01 00 .. 01 7F
ROM Waves 128..255
01 00 .. 01 2B
ROM Waves 256..299
07 68 .. 07 7F
User Waves 1000..1023
08 00 .. 08 7F
User Waves 1024..10151
09 00 .. 09 61
User Waves 1152..1249
------------------------------------------------
So the full format of a WAVR Request is:
Index Label Value Description
------------------------------------------------------
0 EXC F0h
Marks Start of SysEx
1 IDW 3Eh
Waldorf Electronics
GmbH ID
2 IDE 0Eh
Microwave 2 ID
3 DEV
Device ID
4 IDM 02h
here WAVR (Wave
request)
5 HH see Text
Location
6 LL see Text
Location
7 XSUM (HH+LL)&7Fh
Checksum
8 EOX F7h
End of SysEx
------------------------------------------------------
******************************************************
2.32 WAVD
******************************************************
WAVD 12h Wave Dump
A wave dump is used to transfer wave data from and to
the Microwave 2. The location is given in two bytes
with following conventions:
HH LL
Location
------------------------------------------------
00 00 .. 00 7F
ROM Waves 000..127
01 00 .. 01 7F
ROM Waves 128..255
02 00 .. 02 2B
ROM Waves 256..299
07 68 .. 07 7F
User Waves 1000..1023
08 00 .. 08 7F
User Waves 1024..10151
09 00 .. 09 61
User Waves 1152..1249
------------------------------------------------
So the full format of a WAVD Dump is:
Index Label Value Description
------------------------------------------------------
0 EXC F0h
Marks Start of SysEx
1 IDW 3Eh
Waldorf Electronics
GmbH ID
2 IDE 0Eh
Microwave 2 ID
3 DEV
Device ID
4 IDM 12h
here WAVD (Wave
Dump)
5 HH see above Location
6 LL see above Location
7-134 WDATA see 3.4
Wave data
135 XSUM (HH+LL+WDATA)&7Fh Checksum
136 EOX F7h
End of SysEx
------------------------------------------------------
******************************************************
2.41 WCTR
******************************************************
WCTR 03h Wave Control Table Request
Upon reception of a valid wave control table request,
the MW2 will dump the selected Table. The location is
given in two bytes with following conventions:
HH LL Location
-----------------------------------------------------
00 00 .. 00 7F Control Table of Wavetables 001..128
-----------------------------------------------------
Note that some Wavetables are generated
algorithmically and have no control table, an attempt
to request such a table will fail.
The full format of a WCTR Request is:
Index Label Value Description
------------------------------------------------------
0 EXC F0h
Marks Start of SysEx
1 IDW 3Eh
Waldorf Electronics
GmbH ID
2 IDE 0Eh
Microwave 2 ID
3 DEV
Device ID
4 IDM 03h
here WCTR (Wavetable
request)
5 HH see Text
Location
6 LL see Text
Location
7 XSUM (HH+LL)&7Fh
Checksum
8 EOX F7h
End of SysEx
------------------------------------------------------
******************************************************
2.42 WCTD
******************************************************
**************
WAVD 13h Wave ControlDump
A Control Table dump is used to transfer Wavetable
Control Table data from and to the Microwave 2. The
location is given in two bytes with following
conventions:
Содержание MicroWave II
Страница 1: ...Bedienungsanleitung User s Manual ...
Страница 2: ......
Страница 123: ......
Страница 125: ......