background image

 

500.0001-D

 

Technical alterations reserved

 

2.3.4.

 

 Procedure 

The safe is delivered with 4x cylinder screws with an M12x30 internal hex (DIN 912, 
strength grade 8.8), 4x M12 washers (DIN 125 A) and 4x M12x50 drop-in anchors. 
 

  

 

 

 

If it is not possible to use the installation material specified or it is not possible to anchor 
the safe, please consult your property insurance provider to find an alternative anchoring 
solution. 
 
Follow this procedure to anchor the safe into the building wall or floor: 
1.

 

Draw the drilling pattern on the desired position and then drill the anchoring holes with 
Ø15 concrete drill and an impact drill. 

 

The Ø15 drill hole must be at least 54 mm (from the wall/floor) or at least 108 mm 

(from the safe’s 

interior wall) deep. 

2.

 

The EA2 M12x50 drop-in anchor can be hammered in once all four anchoring holes 
have been drilled. 

 

Please consult the manufacturer’s information sheet for hammering in the Fischer 

EA2 M12x50 drop-in anchor (Fischer no.: 48406). 

3.

 

Align the safe with the installation holes in the building wall or the building floor. 

4.

 

If the safe is to be anchored to the building wall, it has to be evenly hammered into the 
wall evenly. 

5.

 

Level out the safe so that the door stands still in any position and does not start to 
swing in one direction (open or closed) on its own. 

 

To do this, place small hardboards (Pavatex) under the corners required. 

6.

 

Attach a washer to each of the cylinder screws and screw them through the anchoring 
sleeve into the drop-in anchor (10mm Allen key) until they line up. 

7.

 

Tighten the cylinder screws to 35 Nm (10mm Allen key), and then tighten them again 
to 35 Nm in the same order to be sure. 
 

 
 
 
 
 
 
 
 

  

 

 

  If the installation material supplied cannot be used owing to the quality of the floor or wall, 

installation has to be adapted to the actual conditions. The dowel used must match the 
type of quality of the building material to be anchored into (minimum requirements for 
threaded rods, screws and dowels M12: Strength grade 8.8, DIN 975 with ISO 7089 

discs). Please observe the manufacturer’s instructions.

 

 

 

Safe wall 

Anchoring sleeve 

Cylinder-head screw 
with washer 

Building wall /  
Building floor 

Drop-in anchor 

Содержание Eco 550

Страница 1: ...www tresore ch INSTALLATION AND MAINTENANCE INSTRUCTIONS WALDIS SAFES RESISTANCE LEVEL II III AS PER EN1143 1...

Страница 2: ...an EN1143 1 certified safe A high quality Swiss product checked and approved by the VdS Please read these instructions carefully before setting up your safe For any questions please contact WALDIS Tr...

Страница 3: ...inst the building wall 3 2 2 Disassembly interior construction 4 2 3 Anchoring the safe 6 2 3 1 Important prior clarification 6 2 3 2 Preparing the safe 6 2 3 3 Table for dimensions anchoring holes 7...

Страница 4: ...hat no body parts get trapped between the doors and the case when opening and closing the doors PLEASE NOTE Before closing the doors make sure that the handle is in the open position and the bolt is r...

Страница 5: ...must be found PLEASE NOTE The safe s warranty and certification terminate after attempted break ins fires and unauthorised interference with the structure 1 4 Operating elements Input unit Handle PLE...

Страница 6: ...door can be opened to 130 If the door needs to be opened 180 observe the minimum distance C from the strip side You can find the minimum distances to observe for your model in the table below Model A...

Страница 7: ...nd neglect the rear wall and the lid Follow this procedure to disassemble the safe CAUTION CUTTING DANGER ON THE METAL SHEETS 1 Open the safe as per the 500 0021 500 0022 instruction manual 2 Pivot th...

Страница 8: ...is separated from the base it can be pulled out of the safe diagonally 6 Repeat Step 5 for the right hand side wall 7 Lift the base slightly and then pull it out of the safe diagonally Make sure to ho...

Страница 9: ...ion Check that the building floor and building wall are suitable for installing the safe and that there are no wires pipes or similar in the area to be drilled In case of doubt an expert report should...

Страница 10: ...el A mm B mm C mm D mm E mm F mm 550 125 250 125 300 129 200 650 125 250 125 400 129 200 801 125 250 125 550 129 200 802 135 350 125 550 138 5 200 1000 135 350 125 750 138 5 200 1200 135 350 125 950 1...

Страница 11: ...the safe with the installation holes in the building wall or the building floor 4 If the safe is to be anchored to the building wall it has to be evenly hammered into the wall evenly 5 Level out the s...

Страница 12: ...rear wall to tilt forwards from the top and then turn it diagonally onto one side Then lift the rear wall and carefully push it into the safe Push the rear wall evenly backwards towards the interior r...

Страница 13: ...e Clip the tabs of the lid onto the top of the right hand side wall and slowly pivot the lid upwards Push the lid slightly to the right while doing this so that it does not align to the left hand side...

Страница 14: ...preparation Alarm control cable 12x 0 14mm2 with approx 5m cable length 3 LED illumination Connection for LED power supply 230V with hollow plug up to size WA 1200 from size WA 1450 Dimensions HxWxD 4...

Страница 15: ...Do not clean with household chemical products Should any mechanical problems or electrical issues occur please consult your trusted specialist dealer or contact WALDIS Tresore AG directly 4 Exemption...

Страница 16: ...by WALDIS at that location WALDIS is obliged to replace the secure storage box concerned but not to cover damages resulting from the theft or additional costs such as transportation and assembly of t...

Отзывы: