translating the .txt Profile 

When opened in a terminal program or text editor, the Lifeline Standard AGM program 

will appear as follows:

#

# LIFELINE  AGM config file

#

Based on details in: Lifeline Technical Manual, rev E

#

Date: 3/17/2020

#

Lifeline standard

100c alternator

#

# Lifeline AGM

$SCA: 0,100,1.00,0.75,0.50,0,0,0,10000,0,0,30,0@

$CPA:7 14.3,360,3,0@

$CPO:7 0, 0, 0.0, 0@

$CPF:7 13.3, -1, 0, 0, -50, 12.5, 0@

$CPE:7 15.5,25,600,0@

$CPP:7 0,0.0,0,0.0@

$CPB:7 0.022, -30, -40, 71, 0.0, -99, -99, 15, 2000@

$SCN: 0,Lifeline,1234@

 

$SCO: 0,0,0,0@

Each line of the .txt file provides commands and values specific to various aspects 

of the charge program. The first line of code, designated as $SCA, changes the 

parameters of the alternator in the table of system configurations. Meanings for the 

values are as follows (note that values are deliniated by commas): 

$SCA: 

0

,

100

,

1.00

,0.75,0.50,0,0,0,10000,0,0,

30

,0@

1

2

3

4

5

6

7

9  10  11 

12 

13 

1.  factory use only

2.  alternator target temperature (°c) – Temperature regulator will attempt to maintain at 

alternator temperature sensor. Contact your alternator manufacturer for recommended 

temperature setting and sensor location. For added system safety, consider setting your 

value 10-20 degrees below the manufacturer’s recommendation.

3.  alternator derate (normal) – When no derate modes are selected.

4.  alternator derate (small alternator mode) – When DIP Switch #8 is selected.

5.  alternator derate (half output) – Selected when alternator temperature sensor wires 

are shorted.

6.  Pull Back factor (PBf) – Reduces field at idle (Set “0” to disable) (Set “1” to enable).

7.  amp cap – (-1

 500) Allows maximum amperage limit if current shunt is connected.

8.  system watts cap – (-1

20000) Limits maximum wattage.

9.  amp shunt ratio – Indicates the current shunt’s ratio (Amps/mVolts) Default setting is 

for a 500A/50mV shunt (500/0.050=10000)

p

a

ge 8 

iMportant: the following information is provided for reference, and is intended 
to provide guidance required to tailor the configuration profile to your system. 
Commonly adjusted settings are highlighted in 

red

. please refer to the Wakespeed 

Communications and Configuration guide for detailed configuration instructions. 

Содержание WS500

Страница 1: ...d a Micro USB cable these configuration files are downloadable from the Wakespeed website and uploaded to the WS500 Regulator Configuring the regulator does not require that the WS500 is installed in...

Страница 2: ...hnical page www wakespeed com technical html Under the table header WS500 Configuration Files is a list of available files broken down by manufacturer and product series When the desired battery profi...

Страница 3: ...configuration profile is found on the Wakespeed website and is downloaded to your computer it should be placed on the computer s desktop Depending on the Windows system being used double click the ZI...

Страница 4: ...ting tha Windows is not allowing the batch file to be opened This can be overridden by clicking the More info link and clicking on the Run anyway button on the next window 2 A new window will open on...

Страница 5: ...cessfully loaded and verified press and release the regulator s reset button 9 Count to five then press any key on the computer s keyboard to load the configuration file for your battery type 10 As sh...

Страница 6: ...warm up delay The percentage of alternator de rate The actual capacity of the batteries being charged Accessing the Configuration file Within the ZIP file is the folder containing the data and Wakesp...

Страница 7: ...not familiar with this process Failure to properly follow guidelines may void your warranty and damage your system The configuration file broken down in the next several pages is intended to provide a...

Страница 8: ...lator will attempt to maintain at alternator temperature sensor Contact your alternator manufacturer for recommended temperature setting and sensor location For added system safety consider setting yo...

Страница 9: ...0 3 0 CPO 7 0 0 0 0 0 1 1 2 2 3 3 4 4 5 5 1 Charge Profile Table Entry Identifies the Profile number being modified by the new configuration Select 7 or 8 2 VBat Set Point Identifies the voltage set p...

Страница 10: ...ing float the delivered amps will be monitored and regulate to the value set Range is 0 50 Zero setting will disable over charge mode 4 Exit Duration Whole number 0 30000 controls timer duration once...

Страница 11: ...loat mode The seventh line of code designated as CPB updates the battery parameters of the regulator s charge profile Meanings for the values are as follows note that values are deliniated by commas C...

Страница 12: ...the normalized value As an example if the battery capacity is 750 amp hours the BC Index should be set at 1 5 5 Maximum Charge Temperature Whole number 20 95 Charging will be discon tinued when measur...

Страница 13: ...system voltage detect 4 Lockout Whole number 0 2 Restricts the ability to perform changes and or pro vide input to the regulator which can impact how the alternator charges the batteries Zero setting...

Отзывы: