The sixth line of code, designated as $CPP, updates the parameters of the Post
Float portion of the charge profile. Meanings for the values are as follows (note that
values are deliniated by commas):
$CPP:
7,0,0.0, 0, 0.0@
1
2
3
5
4
1. charge Profile table entry – Identifies the Profile number being modified by the new
configuration. Select 7 or 8.
2. exit duration – Whole number (0
30000 (500 hours) controls timer duration once
post float stage is entered. When the end of the timed period is reached, the regulator
will loop back to bulk mode. Zero value will cause regulator to remain in Post Float until
triggered by another exit criteria.
3. revert VBat – Floating point number (0.0 to 20.0) designates the minimum Post Float
voltage, below which the regulator will be triggered to return to bulk mode. O.O setting
disables this feature.
4. revert amp-hours – Whole number (-250 to 0) determines the accumulated number of
amp-hours removed during Post Float which will cause the regulator to return to re-start a
charge cycle and return to bulk mode. Setting the value at zero will disable this function.
5. VBat set Point – Floating point number (0.0 to 20.0) designates the target voltage used
during Post Float mode. Setting at 0.0 will disable charging during Post Float mode.
The seventh line of code, designated as $CPB, updates the battery parameters of
the regulator’s charge profile. Meanings for the values are as follows (note that values
are deliniated by commas):
$CPB: 7,0.022,-30, -40, 71, 0.0, -99, -99, 15, 0.0@
1
2
7
8
9
10
6
5
4
3
1. charge Profile table entry – Identifies the Profile number being modified by the new
configuration. Select 7 or 8.
2. VBat compensation – Floating point value (0.0
0.1) adjusts a VBat voltages based
on measured battery temperature. Normalized 12V system with zero correction at
25°C. “0.0” will disable temperature-based voltage compensation.
3. minimum compensated temperature – Whole number (-40
40). Additional volt-
age compensation will be discontinued when measured battery temperature is below
value chosen. Measured in °C.
4. minimum charge temperature – Whole number (-50
10). Charging will be discon-
tinued when measured battery temperature is below value chosen. Measured in °C.
4. exit duration – Whole number (0
600 (10 hours) controls duration regulator will
remain in equalization mode, at which point the regulator will return to float voltage. “0”
will disable this feature.
5. exit amps – Whole number (0
50) Controls minimum delivered current level before
regulator exits equalization to float. “0” will disable this feature. Note: operator is re-
quired to ensure that engine is kept at sufficient RPM to enable delivery of necessary
current to complete equalization, prior to returning to float mode.