$SCN updates the name and password of the regulator. In CANbus communication, 

the regulator name acts as an identifier of the regulator within the CAN network. 

Meanings for the values are as follows (note that values are deliniated by commas): 

$SCO overrides the DIP switches for Charge Profile and Battery Capacity settings, 

and allows the auto-detect for system voltage to be overridden. Values are as follows: 

$CPB: 

0,Lifeline,1234@

$SCO: 

7,

0.0

,0.0,0@

1

1

2

2

3

3

4

1.  reserved – Set at “0”.

2.  regulator name – Up to 18 characters with no spaces, commas, or “@”. This name is 

used for a CAN ID, and may be used to individual regulators in twin engine or other multi-

alternator applications.

3.  regulator Password – Up to 18 characters with no spaces, commas, or “@”. 

1.  charge Profile index – Whole number (0 

 8). Determines charge profile used. Zero 

setting allows DIP switches to be used for charge profile selection.

2.  Battery capacity multiplier index – Floating point number (0.0 

 ±10.0) sets the mul-

tiplier for a normalized 500AH battery bank. Multiplier can be termined by dividing actual 

battery capacity by the normalized value. As an example, if the battery capacity is 750 

amp hours, the BC Index should be set at 1.5. 

5.  maximum charge temperature – Whole number (20 

 95). Charging will be discon-

tinued when measured battery temperature exceeds value chosen. Measured in °C.

6.  rdc Volts – Floating point value (0.0 

 12.0) regulator will work in Reduced Charge 

mode where maximum current delivered will be limited to RDC amps. “0.0” will disable 

this feature.

7.  rdc low temperature – Whole number (-99 

 20). If battery temperature drops 

below the set value in °C, the regulator will work in Reduced Charge mode. “-99” will 

disable this feature.

8.  rdc high temperature – Whole number (-99 

 95). If battery temperature exceeds 

the set value in °C, the regulator will work in Reduced Charge mode. “-99” will disable 

this feature.

9.  rdc amps – Whole number (0 

 100). When the regulator is in Reduced Charge 

mode, acceptance currrent will be limited to the set number. “0” will disable this fea-

ture.

10.  maximum Battery amps – Whole number (0 

 2000). Maximum current allowed to 

flow into the battery. This value is set relative to the 12v/500A ‘nominal’ battery and it   

is also adjusted by the Battery Capacity Multiplier; so a value of 250 would cause the 

regulator to limit charging current to a 0.5c rate. “0” will disable this feature.

p

a

ge 

12 

 

Содержание WS500

Страница 1: ...d a Micro USB cable these configuration files are downloadable from the Wakespeed website and uploaded to the WS500 Regulator Configuring the regulator does not require that the WS500 is installed in...

Страница 2: ...hnical page www wakespeed com technical html Under the table header WS500 Configuration Files is a list of available files broken down by manufacturer and product series When the desired battery profi...

Страница 3: ...configuration profile is found on the Wakespeed website and is downloaded to your computer it should be placed on the computer s desktop Depending on the Windows system being used double click the ZI...

Страница 4: ...ting tha Windows is not allowing the batch file to be opened This can be overridden by clicking the More info link and clicking on the Run anyway button on the next window 2 A new window will open on...

Страница 5: ...cessfully loaded and verified press and release the regulator s reset button 9 Count to five then press any key on the computer s keyboard to load the configuration file for your battery type 10 As sh...

Страница 6: ...warm up delay The percentage of alternator de rate The actual capacity of the batteries being charged Accessing the Configuration file Within the ZIP file is the folder containing the data and Wakesp...

Страница 7: ...not familiar with this process Failure to properly follow guidelines may void your warranty and damage your system The configuration file broken down in the next several pages is intended to provide a...

Страница 8: ...lator will attempt to maintain at alternator temperature sensor Contact your alternator manufacturer for recommended temperature setting and sensor location For added system safety consider setting yo...

Страница 9: ...0 3 0 CPO 7 0 0 0 0 0 1 1 2 2 3 3 4 4 5 5 1 Charge Profile Table Entry Identifies the Profile number being modified by the new configuration Select 7 or 8 2 VBat Set Point Identifies the voltage set p...

Страница 10: ...ing float the delivered amps will be monitored and regulate to the value set Range is 0 50 Zero setting will disable over charge mode 4 Exit Duration Whole number 0 30000 controls timer duration once...

Страница 11: ...loat mode The seventh line of code designated as CPB updates the battery parameters of the regulator s charge profile Meanings for the values are as follows note that values are deliniated by commas C...

Страница 12: ...the normalized value As an example if the battery capacity is 750 amp hours the BC Index should be set at 1 5 5 Maximum Charge Temperature Whole number 20 95 Charging will be discon tinued when measur...

Страница 13: ...system voltage detect 4 Lockout Whole number 0 2 Restricts the ability to perform changes and or pro vide input to the regulator which can impact how the alternator charges the batteries Zero setting...

Отзывы: