a
ge
13
3. sV override – Floating point number (0.0
4.0). This override allows the regulator to
be used in other systems not supported by the auto-detect feature. To determine the SV
multiplier, divide the system voltage by 12. (i.e., a 32V system would be 32/12=2.67).
SV Override must be set at 0.0 to enable auto system voltage detect.
4. lockout – Whole number (0
2). Restricts the ability to perform changes and/or pro-
vide input to the regulator which can impact how the alternator charges the batteries.
Zero setting disables system lockout. A value of one prevents any configuration changes.
A value of 2 creates a lockout level that can only be reversed by reflashing the firmware
with a factory-level key. CAUTION: the only way to recover the regulator from this state
requires special programming hardware probes.