background image

16

6. Hardware Installation

This  Industrial  IEEE  802.3at  Gigabit  High  Power  over  Ethernet  Injector 
provides  three  different  running  speeds  –  10Mbps,  100Mbps  and 
1000Mbps  in  the  same  device  and  automatically  distinguishes  the 
speed  of  incoming  connection.  Please  refer  to  following  sections  for 
detail  information  about  Industrial  IEEE  802.3at  Gigabit  High  Power 
over Ethernet Injector.

Before Installation

Before  your  installation,  it  is  recommended  to  check  your  network 
environment. If there has any IEEE 802.3at devices need to power on, 
the  IPOE-162  can  provide  you  a  way  to  supply  power  for  this  Ethernet 
device conveniently and easily.

If  there  is  very  difficult  to  find  a  power  socket  for  AC-DC  Adapter  to 

your Non-IEEE 802.3at networked device, the IPOE-162 with POE-162S 
/  IPOE-162S  can  provide  you  a  way  to  supply  DC  power  for  this 
Ethernet device conveniently and easily.

Note

The  IPOE-162  with  IPOE-162S  /  POE-162S  is  installed 
in  pair.  However,  the  use  of  third-party  device  is  allowed 
if  the  device  complied  with  IEEE  802.3at  Power  over 
Ethernet.

IPOE-162 Injector Installation

1. Connect  the  Power  (Range  from  AC  24V  or  DC  24  ~  48V)  to  6-pin 

terminal block of IPOE-162. The power LED will be steady on.

2. Connect  a  standard  network  cable  from  Switch  /  workstation  to 

“Ethernet”

 port of IPOE-162.

3. Connect  the  long  cable  that  will  be  used  to  connect  to  the  remote 

device to the port 

“Et DC”

.

4. Due to the capability of IEEE 802.3at Power over Ethernet, the IPOE-

162  can  directly  connect  with  any  IEEE  802.3at  /  IEEE  802.3af  end-
nodes  such  as  PTZ  (Pan,  Tilt  &  Zoom)  network  cameras,  PTZ  Speed 
Dome,  color  touch-  screen  Voice  over  IP  (VoIP)  telephones,  multi- 
channel wireless LAN access points.

Содержание IPOE-162

Страница 1: ...orgung zu den Touch Panels TP 7 und TP 10 mittels Power over Ethernet Das Ger t wird in der Verteilung eingebaut Es ben tigt eine Spannungsversorgung 24VDC Es wird in die LAN Verbindung von der Zentra...

Страница 2: ...Industrial IEEE 802 3at af Gigabit PoE Injector IPOE 162 User s Manual...

Страница 3: ...ysical Dimension 8 4 2 Product Outlook 9 4 3 Industrial PoE Injector Upper Panel 10 4 4 Wiring the Power Inputs 10 4 5 Wiring the Fault Alarm Contact 12 5 Mounting Installation 13 5 1 DIN Rail Mountin...

Страница 4: ...njector and carefully unpack it The box should contain the following items IPOE 162 Industrial IEEE 802 3at Gigabit High Power over Ethernet Injector x 1 l l User s Manual x 1 l l DIN Rail Kit x 1 l l...

Страница 5: ...Span PSE IEEE 802 3at 802 3af PoE compliant IEEE 802 3at 802 3af splitter devices compatible Support PoE Power up to 30 Watts for PoE port Provides DC 56V power over RJ 45 Ethernet cable to device wi...

Страница 6: ...ration temperature Note PD Powered Device is a PoE enabled terminal by PSE and thus consumes energy such as IP Phones network cameras and Wireless access points etc PSE Power Sourcing Equipment is a d...

Страница 7: ...3 4 5 up to 100m 328ft 100Base TX UTP Cat 3 4 5 up to 100m 328ft 1000Base T UTP Cat 5 5e 6 up to 100m 328ft EIA TIA 568 100 ohm STP 100m Data Rate 10 100 1000Mbps Dimension W x D x H 135 x 97 x 32 mm...

Страница 8: ...02 3ab 1000Base T Gigabit Ethernet IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet enhancement standard FCC FCC Part 15B Class A CE EMI EN 55022 EN 61000 3 2 EN 61000 3 3 EMS EN 6100...

Страница 9: ...ion Side View Bottom View Front View Top View Mounting Kit Mounting Kit DIN Rail Kit Rear View 10 100 1000T 10 100 1000T Ethernet DC Ethernet PoE In Use IPOE 162 P1 P2 FAULT 802 3at Input DC 24 48V AC...

Страница 10: ...E 162 P1 P2 FAULT 802 3at Figure 4 2 LED Indicators LED Color Function P1 Green Indicate the power 1 has power P2 Green Indicate the power 2 has power FAULT Green Indicate the either power 1 or power...

Страница 11: ...power inputs Figure 1 shows the upper panel of the Industrial PoE Injector 1 2 3 4 5 6 Figure 1 Industrial PoE Injector Upper Panel 4 4 Wiring the Power Inputs The 6 contact terminal block connector...

Страница 12: ...for POWER 1 or 5 and 6 for POWER 2 1 2 3 4 5 6 Figure 2 Power input PINs 2 Tighten the wire clamp screws for preventing the wires from loosing 1 2 3 4 5 6 Power 1 Fault Power 2 Figure 3 PWR1 PWR2 Pin...

Страница 13: ...t status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts Insert the wires into the fault alarm contacts...

Страница 14: ...PLANET 8 Port Industrial Gigabit Switch as the example However the steps for PLANET Industrial slim type Switch Industrial Media Serial Converter and Industrial PoE equipment are similar 5 1 DIN Rail...

Страница 15: ...track Figure 7 Industrial Equipment installed in DIN Rail mount 5 2 Remove DIN Rail Mounting Step 1 Please refer to following procedures to remove the Industrial Equipment from the track 1 2 Figure 8...

Страница 16: ...dustrial Equipment loose the screws to remove the DIN Rail Step 2 Place the wall mount plate on the rear panel of the Industrial Equipment Figure 9 Attach Brackets to the Industrial Equipment Step 3 U...

Страница 17: ...ed device the IPOE 162 with POE 162S IPOE 162S can provide you a way to supply DC power for this Ethernet device conveniently and easily Note The IPOE 162 with IPOE 162S POE 162S is installed in pair...

Страница 18: ...acceptable DC power range is from 52 to 56V DC Otherwise it will damage the Powered Device PD 2 If the connected device PD is not fully complying with IEEE 802 3at Power over Ethernet or in line powe...

Страница 19: ...or will remains on Power Line 1000Base T UTP PoE 1000Base T UTP with PoE IPOE 162 Industrial Switch Power Supply AC 24V DC 24 48V IPOE 162 IPOE 162S Installation 40 75 802 3at PoE Splitter Power Data...

Страница 20: ...t information please contact PLANET switch support team PLANET online FAQ http www planet com tw en support faq php type 2 Switch support team mail address support_switch planet com tw Copyright PLANE...

Страница 21: ...22 Class A 2010 EN 55024 2010 IEC 61000 4 2 2008 IEC 61000 4 3 2006 A1 2007 A2 2010 IEC 61000 4 4 2004 A1 2010 IEC 61000 4 5 2005 IEC 61000 4 6 2008 IEC 61000 4 8 2009 Responsible for marking this dec...

Отзывы: