213.805.022
19
Date: 2022-09-19
MODE
Function
Description
Note
0
Neutral Mode
The motor is not powered, and the winch does not move.
1
Positioning
AUTO reset
The winch resets automatically and thereby also set the soft
TOP limit automatically.
The winch runs up until the snap hook reaches the motor-
house and stops. Because of this, the soft TOP limit in this
MODE will always be at the motor-house.
To start the automatic resetting, speed must be added on the
speed-channel (DMX channel 3).
When the winch has been reset, it is possible to use it in
positioning mode.
2
Positioning
MANUAL reset
The winch is manually reset on the DMX channels 6 or 7.
The soft TOP limit is, because of this, also set manually, which
makes it possible to decide the position of the soft TOP limit.
It is highly recommended to set the top position at the motor-
house. When the winch has been reset, it is possible to use it in
positioning mode.
WARNING!
When
resetting in MODE
2, decrease the
speed, as the load
is closing in on the
winch, otherwise
the lifting cable
and winch can be
damaged
3
Positioning (8 bit)
AUTO reset
As MODE 1, but only 8-bit. Use only this MODE if you do not
have a 16-bit lightning desk.
4
Positioning (8 bit)
MANUAL reset
As MODE 2, but only 8-bit. Use only this MODE if you do not
have a 16-bit lightning desk.
5,6
No function assigned
The winch stops
7
Manual run up
(no DMX needed)
The winch runs up with the speed set on the DMX-selectors.
This function can be used as a test-function or in association
with on- and off-applying of lifting cable.
E.g. Set the winch to MODE 7 and the DMX address to 100, for
a slow movement, or set the DMX address to 500 for fast
movement.
WARNING!
Only
for service and
tests!
8
Manual run up
(no DMX needed)
The winch runs down with the speed set on the DMX-selectors.
This function can be used as a test-function or in association
with on- and off-applying of lifting cable.
E.g. Set the winch to MODE 8 and the DMX address to 100, for
a slow movement, or set the DMX address to 500 for fast
movement.
WARNING!
Only
for service and
tests!
9
Re-calibrating overload See page 23
WARNING!
Only
for service and
tests!
Table 2 - Overview of MODE functions
Содержание Winch 10 Cable
Страница 2: ...213 805 022 2 Date 2022 09 19...
Страница 31: ......
Страница 39: ...213 805 022 39 Date 2022 09 19 Appendix 1 Winch 10 cable 4 m 212...
Страница 40: ...213 805 022 40 Date 2022 09 19 Appendix 2 Winch 10 cable 10 m 213...
Страница 41: ...213 805 022 41 Date 2022 09 19 Appendix 3...
Страница 42: ...213 805 022 42 Date 2022 09 19...
Страница 43: ...213 805 022 43 Date 2022 09 19 Appendix 4...
Страница 44: ...213 805 022 44 Date 2022 09 19 Appendix 5 A block diagram of the control system of the winch...
Страница 45: ...213 805 022 45 Date 2022 09 19 This page is intentionally left blank...