356.805.003
17
Date: 2019-04-04
DMX channel overview
DMX
channel
Function
Description
1
Position rough
This channel controls the position of the unit, with the speed (DMX channel 3).
This rough position works together with the fine position (DMX channel 2).
The rough position and the fine position are multiplied in to a 16 bit channel. The rough
position is the
MSB
.
2
Position fine
This channel controls the position of the unit, with the speed set on DMX channel 3.
This fine position works together with the rough position (DMX channel 1).
The fine position and the rough position are multiplied in to a 16 bit channel. The fine
position is the
LSB
3
Speed
This channel controls the speed of the unit.
This channel defines the maximum speed, and the motor slows down as closing in on the
wanted position.
This channel also works as a main brake; the motor does not run unless the channel is set
above 0%. The speed-channel can also be used to make soft and slow movements or fast
and sudden movements.
4
Manuel Down
/ Set soft-limit
low (0%
position)
The value of the channel determines the speed at which the unit moves. This channel
overrules movement with positioning via channel 1 & 2.
•
Channel 6
between
51-54% enable save soft-limits.
When channel 6 is in this range the lower position can be adjusted using channel 4.
The lowest position is saved when channel 4 is put back at 0%. Note that it should be
moved gradually towards 0% to give the motor time to slow down.
The lowest position should be set with channel 4 before the highest position is set
with channel 5, since the range is calculated relative to the lowest position.
•
Channel 6
not between
51-54% enable save soft-limits is
NOT
enabled.
When save position is not enabled, channel 4 can still run the motor but any position
is not saved, so it returns to the position given by channel 1 &2.
5
Manuel Up /
Set soft-limit
high, and
range (100%
position)
The value of the channel determines the speed at which the unit moves. This channel
overrules movement with positioning via channel 1 & 2.
•
Channel 6
between
51-54% enable save soft-limits.
When channel 4 is in this range the end position can be adjusted when running with
channel 5. The highest position is set when channel 5 is put back at 0%.
The lowest position should be set with channel 4 before the highest position is set
with channel 5, since the range is calculated relative to the lowest position.
•
Channel 6
not between
51-54% enable save soft-limits is
NOT
enabled.
When save position is not enabled, channel 5 can still run the motor but any position
is not saved, so it returns to the position given by channel 1 & 2.
6
Enable save
soft-limits
When channel 6 is between 51-54% saving of soft-limit low and high position is enabled.
The unit can be operated while channel 6 is between 51-54%, however, to minimise the risk
of accidentally setting new low and high limits, channel 6 should be set to 0% when not in
use.