245.805.011 

16 

Date: 2021-12-09

 

 

WARNING! By default, the emergency stop is NOT enabled! 

 

The Winch 50 Series can be configured with an emergency stop; by default, the emergency stop 
is not enabled.  

 

The DMX control from a lighting desk should always have a set up so there is a button that sets 

the speed of the winch in operation to 0%. Normally lighting desks 

sets all intensity channels to 0% and this will also cause the winch to stop when assigned correctly.

 

 

If the emergency stop switch is activated the red Error LED will be lit and the screen display shows: 

 and the current start channel of the unit: 

 

 

 

The emergency stop switch is connected to the male 4 pole XLR connector on the winch. Pin 1 and 

Pin 4 should be powered with 12-15 Volt DC to enable operation of the winch. 

 

Pin out: 

Connection 

 

Pin 1 

GND 

Pin 2 

Not connected 

Pin 3 

Not connected  

Pin 4 

12-15 V DC 

 

 

 

The  emergency  stop  power  supply  and  plug  is  available  for  purchase  from  Wahlberg  Motion 
Design. 

 
 

 

 

Содержание 50 Series

Страница 1: ...JUULS VEJ 1 TELEPHONE 45 86 18 14 20 8260 VIBY EMAIL sales wahlberg dk DENMARK Winch 50 Series Item No 245 246 701 and 246 704 User Manual Winch 50 Winch 50 Double Winch 50 Double No 245 No 246 701 P...

Страница 2: ...rig or structure as described in this manual Ensure that any supporting hardware can hold at least 10 times the weight of all the devices they support Block access below the work area whenever install...

Страница 3: ...CY STOP SWITCH OPTIONAL 16 ENABLE EMERGENCY STOP 17 LIFTING WIRE POWER ETHERNET ONLY MODEL 246 704 17 LIFTING CABLE CONNECTION PLUG 17 CONNECTING THE POWER WIRE 17 SETUP 18 MENU SETTING 18 MENU STRUCT...

Страница 4: ...N F Output Neutrik powerCON TRUE1 EtherCON M Power 16A 240VAC 2x1 5mm2 AWG 16 Signal Two twisted pairs Cat5 100 Mbit s Lifting capacity 50 kg 110 2 lb Lifting height 12 5 m 41 ft Lifting speed 3 84 cm...

Страница 5: ...245 805 011 5 Date 2021 12 09 Winch 50 245 More detailed drawings and from more angles can be found in Appendix 1 on page 37...

Страница 6: ...245 805 011 6 Date 2021 12 09 Winch 50 Double 246 701 More detailed drawings and from more angles can be found in Appendix 2 on page 38...

Страница 7: ...245 805 011 7 Date 2021 12 09 Winch 50 Double Power and Cat5 246 704 More detailed drawings and from more angles can be found in Appendix 3 on page 39...

Страница 8: ...nches a standard lighting desk can be used but when many winches are used more advanced desks should be used to maintain easy control of the units The Winch 50 Series uses 6 channels of the DMX line a...

Страница 9: ...persons or equipment damage Exceeding the load rating may cause failure of the equipment Use only the Wahlberg Motion Design approved mounting connectors to secure the load to the winch Failure to mo...

Страница 10: ...re transport it is important to roll the wire of the winch up fix the wire with a cable tie or an elastic cord If the wire is slack it may jump off the drum during transport and cause damage to the wi...

Страница 11: ...ight of all products and equipment to be installed on it Mounting the product on a truss The Winch 50 Series can be clamped to a truss or similar rigging structure To clamp a product to a truss 1 Chec...

Страница 12: ...TION The load must be mounted on the wire in a way to secure that the load never can run into the winch The load can be mounted using a suitable loading hook designed for lifting Ensure that the loadi...

Страница 13: ...ble connector for AC mains power input The cable must rated 20A minimum have three conductors 1 5mm2 AWG 16 minimum conductor size and an outer cable diameter of 6 16mm 0 24 0 47 inch Cables must be h...

Страница 14: ...ce showing the product name Followed by a screen showing the software version e g SW 503 002 012 as shown below Then a description of how to enter the menu Before it is ready to be controlled by DMX c...

Страница 15: ...a DMX universe and another daisy chained link Tips for reliable data transmission Use shielded twisted pair cable designed for RS 485 devices standard microphone cable cannot transmit control data rel...

Страница 16: ...nnels to 0 and this will also cause the winch to stop when assigned correctly If the emergency stop switch is activated the red Error LED will be lit and the screen display shows and the current start...

Страница 17: ...so that the lifting wire attachment can easily be disconnected from power Warning Check that the voltage range specified for the lifting wire matches the attached power voltage before applying power t...

Страница 18: ...G Only experienced DMX users should operate the product Contact Wahlberg Motion Design for further information and education on DMX protocol Menu setting Use the buttons on the display to enter and ch...

Страница 19: ...urrent position with tachometer value 10 000 and the wanted position has the tachometer value of 24 250 Shift to next screen press and hold The screen shows the DMX channel values if e g DMX channel 1...

Страница 20: ...otor is stopped and DMX input has no effect the motor can be moved by the MANUAL RUN GOING UP GOING DOWN menu though Press the arrows or to go up or down in the menu choices The bottom line of the dis...

Страница 21: ...le disable emergency stop OFF ON OFF ADV MENU Show advanced menu OFF ON OFF SLACK DELAY Delay from slack activation to stop 0 9999 0 POS OUT Position feedback OFF ON OFF UNSAFE MODE Disable all limit...

Страница 22: ...SP MIN UP Minimum speed up Range 50 1 000 The motor minimum speed for the up direction The motor can run at different minimum speeds for each direction this is to differentiate between different mech...

Страница 23: ...K SLACK Stop quickly when slack activates OFF ON Stops the winch quickly if slack is enabled If the load is light or fast accelerations are used slack may be activated by accident leading to a stutter...

Страница 24: ...ed before shutdown the soft top limit must be set again when the unit is powered on 5 Setting the soft TOP limit Channel 5 is used to manually move the fabric up and setting the soft TOP When the valu...

Страница 25: ...et in a position where the load can run into the winch itself this will damage the winch For guidance see below illustration of the soft and hard limits Figure 1 Illustration of the hard and soft limi...

Страница 26: ...in the unit whenever a setup procedure has been initiated by using DMX channel 5 and 6 About the hard limits The hard limit switch determines the maximum and minimum travel distance of the winch The h...

Страница 27: ...a 1 next to it 6 The hard TOP limit is adjusted by turning the screw with a 2 next to it 7 When adjustments are done tighten the middle screw again 8 Mount the lid with the two screws again The hard l...

Страница 28: ...th in minutes E g a max duty cycle of 30 10 min ON 23 min OFF means that the motor may not be active more than 10 minutes every 33 minutes or after 10 minutes of ON the motor must be OFF for 23 minute...

Страница 29: ...one position to another over a certain amount of time In that way the Winch 50 Series will follow the fade curve and multiple Winch 50 Series can follow the same fade curve When fading the positions 1...

Страница 30: ...m while inspecting that the wire comes out of the winch evenly Afterwards the wire is rolled back onto the drum Reset the top position afterwards The winch cannot move to its position this usually occ...

Страница 31: ...mperature is below 10 C Make sure to warm up electronic equipment to room temperature before applying power 14 DRIVE OVER TEMP Shut down due to inverter overheat The temperature of the power electroni...

Страница 32: ...ENTIFICATION Motor identification run has failed See remedy for No 3 The motor identification has already been initiated once at the manufacturing facility Repeating the identification procedure may o...

Страница 33: ...wire to wear down faster and shortens the lifetime of the wire significantly Wire damage caused by mounting the winch in an angle is not covered by the product warranty Attention Signs of malfunction...

Страница 34: ...is wound neatly on the drum Check the wire ferrule crimp and thimble Check that the load is securely mounted Monthly At regular intervals but at least every month when the Winch 50 Series is in use C...

Страница 35: ...e wire should be discarded when When the overall diameter of the is reduced by 8 or the outer wires have lost its diameter by 33 through wear This reduction in diameter of the is measured on a portion...

Страница 36: ...rely worn or damaged that it is possible to insert the cable connector the wrong way However when inserted the wrong way the cable connector should not twist lock into place A cable connector inserted...

Страница 37: ...245 805 011 37 Date 2021 12 09 Winch 50 245...

Страница 38: ...245 805 011 38 Date 2021 12 09 Winch 50 Double 246 701...

Страница 39: ...245 805 011 39 Date 2021 12 09 Winch 50 Double Power and Cat5 246 704...

Страница 40: ...245 805 011 40 Date 2021 12 09...

Страница 41: ...245 805 011 41 Date 2021 12 09...

Страница 42: ...DMX signal in XLR 5 pole Control input DMX signal Controller Motor controller Encoder Gear M Power supply Emergency Stop Manuel Control B Power in Bar powerCON TRUE 1 Cat5 in Bar EtherCON Cat5 out Bar...

Страница 43: ...245 805 011 43 Date 2021 12 09 This page is intentionally left blank...

Страница 44: ...travel range has now been set from the soft TOP limit to the soft BOTTOM limit 7 Set DMX channel 1 to 100 and DMX channel 3 to 20 The winch moves with 20 speed to the 100 position 8 Set DMX channel 1...

Отзывы: