To ensure fast installation and start-up of the units described in this manual, 
we strongly recommend that the following information and explanations are 
carefully read and abided by. 

1.1 Legal Principles 

1.1.1 Copyright 

This manual is copyrighted, together with all figures and illustrations 
contained therein. Any use of this manual which infringes the copyright 
provisions stipulated herein, is not permitted. Reproduction, translation and 
electronic and photo-technical archiving and amendments require the written 
consent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will 
entail the right of claims for damages. 

WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform 
modifications allowed by technical progress. In case of grant of a patent or 
legal protection of utility patents all rights are reserved by WAGO 
Kontakttechnik GmbH & Co. KG. Products of other manufacturers are always 
named without referring to patent rights. The existence of such rights can 
therefore not be ruled out. 

1.1.2 Personnel Qualification 

The use of the product detailed in this manual is exclusively geared to 
specialists having qualifications in PLC programming, electrical specialists or 
persons instructed by electrical specialists who are also familiar with the valid 
standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability 
resulting from improper action and damage to WAGO products and third party 
products due to non-observance of the information contained in this manual. 

1.1.3 Intended Use 

For each individual application, the components supplied are to work with a 
dedicated hardware and software configuration. Modifications are only 
permitted within the framework of the possibilities documented in the 
manuals. All other changes to the hardware and/or software and the non-
conforming use of the components entail the exclusion of liability on part of 
WAGO Kontakttechnik GmbH & Co. KG. 

Please direct any requirements pertaining to a modified and/or new hardware 
or software configuration directly to WAGO Kontakttechnik GmbH & Co. 
KG. 

Содержание I/O-SYSTEM 751-3002

Страница 1: ...AS Interface Components IP67 AS Interface Module 4IN 24V A B 751 3002 Manual Version 1 1 0...

Страница 2: ...hone 49 0 571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can...

Страница 3: ...bols 6 1 3 Number Notation 6 1 4 Safety Notes 7 1 5 Scope 7 2 AS Interface Components 8 2 1 AS Interface Module IP67 8 2 1 1 751 3002 AS Interface Module 4IN 24V A B 8 2 1 1 1 View 8 2 1 1 2 Descripti...

Страница 4: ...Connector gqxxx01x 9 Fig 2 1 1 3 Display Elements gq30012x 10 Fig 2 1 1 4 Schematic Diagram gq30021e 11 Fig 2 1 1 5 Characteristic Input Curve gqxxx15e 14 Fig 2 1 1 6 Dimensions gqxxx08x 14 Fig 2 1 1...

Страница 5: ...ther manufacturers are always named without referring to patent rights The existence of such rights can therefore not be ruled out 1 1 2 Personnel Qualification The use of the product detailed in this...

Страница 6: ...oth operation ESD Electrostatic Discharge Warning of damage to the components by electrostatic discharge Observe the precautionary measure for handling components at risk Note Routines or advice for e...

Страница 7: ...ponent environment then additional measures are to be taken handling of the components only with clean tools and materials Attention Cleaning of soiled contacts may only be done with ethyl alcohol and...

Страница 8: ...dule 751 3002 is an economical solution for a fieldbus independent and flexible connection of sensors from the field and the control cabinet The module is in accordance with AS Interface specification...

Страница 9: ...e sockets Tab 2 1 1 1 Sensor Connectors Sensor Connectors Connector Pin Function IN 1 3 IN 2 4 1 Sensor supply L IN 1 3 2 Sensor signal from IN 2 4 Pin 4 IN 1 3 IN 2 4 3 Sensor supply L IN 1 3 IN 2 4...

Страница 10: ...al voltage 0 IN 1 yellow Status DI1 on Input 1 Signal voltage 1 off Input 2 Signal voltage 0 IN 2 yellow Status DI2 on Input 2 Signal voltage 1 off Input 3 Signal voltage 0 IN 3 yellow Status DI3 on I...

Страница 11: ...AS Interface Components IP67 2 1 1 6 Schematic Diagram Sensor Sensor 1 4 2 3 5 1 4 2 3 5 IR FE FE ASI FID FAULT IN IN1 IN2 IN1 NTERFACE IN IN3 IN4 IN3 IN IN2 IN2 IN IN4 IN4 IN IN IN IN AS i AS i ASI I...

Страница 12: ...l voltage 0 5 V Signal voltage 1 11 V Connection system Socket M12 x 1 5 pole AS Interface Operating voltage AS I 26 5 V 31 6 V Current consumption type 35 mA Current consumption max 50 mA start up 23...

Страница 13: ...C 60068 2 27 EMC Immunity to interference CE acc to EN 61000 6 2 EMC Emission of interference CE acc to EN 61000 6 3 Approvals AS Interface Association Specification V3 0 ZU No 72502 CULUS UL508 Confo...

Страница 14: ...omponents IP67 Tab 2 1 1 3 Technical Data Characteristic Input Curve 0 5 10 15 20 V 2 0 2 4 6 8 mA 25 30 Input Voltage Input Voltage Input Current Input Current Fig 2 1 1 5 Characteristic Input Curve...

Страница 15: ...e cutouts that are marked for this purpose Make sure that the cables engage behind the locking latch For modules with unused AUX socket insert the enclosed blanking cap to seal the cable entry 3 Fix t...

Страница 16: ...ation may lead to malfunctions or restrictions Please note the AS interface master manual and the manual for the start up tool WAGO I O CHECK 2 759 302 for start up and diagnosis of the AS interface s...

Страница 17: ...751 3002 AS Interface Module 4IN 24V A B 17 Start up and diagnosis WAGO I O SYSTEM 751 AS Interface Components IP67...

Страница 18: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Отзывы: