Commissioning 37
752-9800
Manual
Version 1.0.0
8.2
Configuration
8.2.1
Configure Locally in the Terminal
After booting the system (Debian Linux 10.x), the operating system terminal
opens automatically (default).
Log in to configure the Edge computer locally.
Figure 5: Terminal Login Screen
8.2.2
Web-Based Configuration with Cockpit
The HTML pages (hereinafter referred to as “pages”) of the “Cockpit”
visualization tool (Web-Based Management) are used to configure the computer.
To access the Cockpit via a Web browser, proceed as follows:
1. Connect the Edge computer to your PC via the ETHERNET interface and
the ETHERNET network.
2. Start a Web browser on your PC.
3. Enter “https://" in the address line of your Web browser, followed by the IP
address of the Edge computer and port number “9090”, e.g.,
“https://192.168.2.17:9090”.
Note that the PC and the Edge computer must be on the same subnet.