WAGO Industrial Switches
Important Notes 11
852-1417 Industrial Eco Switch
Manual
Version 1.2.1
2.2
Safety Advice (Precautions)
For installing and operating purposes of the relevant device to your system the
following safety precautions shall be observed:
Do not work on devices while energized!
All power sources to the device shall be switched off prior to performing any
installation, repair or maintenance work.
Only install in appropriate housings, cabinets or electrical operation
rooms!
WAGO's 852 Series ETHERNET Switches are considered exposed operating
components. Therefore, only install these switches in lockable housings, cabinets
or electrical operation rooms. Access must be limited to authorized, qualified staff
having the appropriate key or tool.
Ensure a standard connection!
To minimize any hazardous situations resulting in personal injury or to avoid
failures in your system, the data and power supply lines shall be installed
according to standards, with careful attention given to ensuring the correct
terminal assignment. Always adhere to the EMC directives applicable to your
application.
Do not use in telecommunication circuits!
Only use devices equipped with ETHERNET or RJ-45 connectors in LANs.
Never connect these devices with telecommunication networks.
Replace defective or damaged devices!
Replace defective or damaged device/module (e.g., in the event of deformed
contacts).