6
Connect Devices
6.1
Power Supply
The switch uses direct-current power supply for 24 … 57 V.
The primary network link is established via a 2-pin plug-in connection located on
the top of the switch.
The female connector (order-no. 2231-102/026-000) is composed of two
connecting terminals and can be inserted and removed easily by hand to connect
to the 2-pin plug connector located on the top of the switch.
The power supply for the switch automatically adjusts to the local power source
and can also be switched on if no or not all patch cables are connected.
1.
Connect a suitable grounding conductor to the grounding lug on the top of
the switch.
Ground for the switch
The ground for the switch prevents electromagnetic interference from
electromagnetic radiation.
Observe the corresponding standards for EMC-compatible installations as well.
2.
Plug the female connector into the male connector of the switch if it has not
already been plugged in. Check the tight fit of the multipoint connector by
gently shaking it.
3.
PWR +/-:
To connect or disconnect the conductors, actuate the spring directly in the
female connector using a screwdriver or an operating tool and insert or
remove the conductor.
4.
Check whether the power LED “PWR” on the top of the device lights up
when power is supplied to the device. If not, check to ensure that the power
cable is plugged in correctly and fits securely.