40
Connecting Data and Supply Cables
WAGO-SPEEDWAY 767
767-4801/000-800 8DO 24V DC 0.5A IF (8xM8)
Manual
Version 1.1.0
•
Do not use drop lines under any circumstances. This can lead to amplified
line reflections and signal distortions, which greatly impair the transmission
quality.
Pos: 23.9 /Serie 767 (WAGO-SPEED WAY)/Anschl uss D aten- und Versorgungskabel/I/O-Modul e/Anschl uss_Hinweise T eil 3.1 @ 8\mod_1278314911479_21.docx @ 58959 @ @ 1
•
Observe the exact positioning (coding) between plug and socket.
•
Keep all cables a sufficient distance away from electromagnetic sources of
interference in order to maintain a high level of interference resistance of
the 767 system against electromagnetic emissions.
•
Observe the minimum bending radiuses of the WAGO system cable. For
more information, see the technical data at www.wago.com.
•
When laying all cable, ensure that you do not lay it in shear areas of moving
machine parts.
•
Observe the correct layout of the potential equalization.
Pos: 23.10 /Serie 767 ( WAGO-SPEED WAY)/Anschluss D aten- und Versorgungskabel/I/O-M odule/Anschluss_Z ubehör allgemein @ 5\mod_1249287357968_21.docx @ 39869 @ 2 @ 1
5.2
Required Accessories
The WAGO accessories listed below are required for connecting the data and
supply cable. The associated item numbers can also be found in the fieldbus
manuals for 767 Series, in the "Accessories" section. Select the manual
appropriate to the 767 Series fieldbus you are using.
•
S-BUS M12 terminator, IP 67
•
S-BUS and supply cables, pre-assembled on both ends, IP 67
•
Torque wrench
•
Protective caps
Pos: 23.11 /D okumentati on allgemei n/Gli ederungsel emente/---Seitenwechsel--- @ 3\mod_1221108045078_0.docx @ 21810 @ @ 1